6-9
Set Values
•
These parameters prevent the motor from over excitation due to voltage changes during energy-sav-
ing control.
•
Set the upper limit of output voltage in percentage at each frequency based on the rated motor voltage
as 100%.
•
Normally, the default settings do not need to be changed.
Output voltage
upper limit (%)
Output frequency (Hz)
n144
Probe Operation Voltage Limit
Register
0190 Hex
Changes during
operation
No
Setting
range
0 to 100 (%)
Unit of
setting
1%
Default setting
0
Set Values
•
When the output frequency is constant for a certain period while the Inverter is in effective energy-sav-
ing control, the Inverter will be set to the primary level of energy-saving control by n140 (energy-saving
constant K2). Then the Inverter will be set to the secondary level (i.e., probe operation) for more effi-
cient, energy-saving control. Set the control voltage range of the Inverter in probe operation in param-
eter n144.
•
Set the upper limit of probe operation voltage in percentage based on the rated motor voltage as
100%. Normally set the value to approximately 10%.
•
No probe operation will be available if the value is set to 0.
n145
Probe Operation Control Voltage
Step at 100%
Register
0191 Hex
Changes during
operation
No
Setting
range
0.1 to 10.0 (%)
Unit of
setting
0.1%
Default setting
0.5
n146
Probe Operation Control Voltage
Step at 5%
Register
0192 Hex
Changes during
operation
No
Setting
range
0.1 to 10.0 (%)
Unit of
setting
0.1%
Default setting
0.2
Advanced Operation
Chapter 6
Summary of Contents for SYSDRIVE 3G3MV-A2001
Page 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Page 2: ......
Page 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Page 18: ......
Page 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Page 32: ......
Page 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 74: ......
Page 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 102: ......
Page 142: ......
Page 242: ......
Page 268: ......
Page 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 303: ...Chapter 10 List of Parameters 10...
Page 337: ...Chapter 11 Using the Inverter for a Motor 11...
Page 343: ......
Page 344: ...I527 E1 04...