6-43
Frequency Jump Function
Output
frequency
Reference frequency
6-10-7 Accumulated Operating Time (n087, n088)
•
The accumulated operating time function is provided for 5.5- and 7.5-kW Inverters only.
•
This function calculates and stores in memory the Inverter’s accumulated operating time. The accu-
mulated operating time that is saved can be checked (unit: 10h) by the “accumulated operating time”
(U-13) of the multi-function monitor (MNTR indicator).
•
Use this function in determining the maintenance schedule.
n087
Accumulated Operating Time
Register
0157 Hex
Changes during
operation
No
Setting
range
0, 1
Unit of
setting
1
Default setting
0
Set Values
•
Select the operation status to be accumulated.
Value
Description
0
Accumulate the Inverter’s power-ON time (the time from when the power is turned ON until
it is shut OFF).
1
Accumulate the Inverter’s RUN time (the time that the RUN command is being input).
n088
Accumulated Operating Time
Selection
Register
0158 Hex
Changes during
operation
No
Setting
range
0 to 6,550
Unit of
setting
10 H
Default setting
0
•
Set the initial value for the accumulated operating time with 10 hours set as 1. The accumulation will
begin from the time that is set.
Note
To clear (i.e., set to 0) the monitor value (U-13) for the accumulated operating time, set n088 to 0.
The monitor value cannot be cleared by setting n001 (parameter write-prohibit selection/parame-
ter initialization) to 8 or 9 (initialize).
Advanced Operation
Chapter 6
Summary of Contents for SYSDRIVE 3G3MV-A2001
Page 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Page 2: ......
Page 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Page 18: ......
Page 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Page 32: ......
Page 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 74: ......
Page 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 102: ......
Page 142: ......
Page 242: ......
Page 268: ......
Page 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 303: ...Chapter 10 List of Parameters 10...
Page 337: ...Chapter 11 Using the Inverter for a Motor 11...
Page 343: ......
Page 344: ...I527 E1 04...