10-18
Para
me-
ter
No.
Reg-
ister
No.
(Hex)
Name
Description
Set-
ting
range
Unit
of
set-
ting
Defaul
t set-
ting
Chan-
ges dur-
ing
opera-
tion
Ref-
er-
ence
page
n060
013C
Frequency
reference
gain
Used to set the input characteristics of analog
frequency references.
Gain: The frequency of maximum analog input
(10 V or 20 mA) in percentage based on the
0 to
255
1%
100
Yes
5-13
n061
013D
Frequency
reference
bias
(10 V or 20 mA) in percentage based on the
maximum frequency as 100%.
Bias: The frequency of minimum analog input
(0 V or 0 or 4 mA) in percentage based on the
maximum frequency as 100%.
–100
to 100
1%
0
Yes
5-13
n062
013E
Analog fre-
quency ref-
erence fil-
ter time
constant
Used to set the digital filter with a first-order lag
for analog frequency references to be input.
0.00
to
2.00
0.01 s
0.10
Yes
5-14
n063
---
Not used
---
---
---
---
---
---
n064
0140
Frequency
reference
loss detec-
tion (See
note.)
Selects the frequency loss detection function
for when the frequency reference from the con-
trol circuit terminal suddenly drops.
0: Disable (Operate according to frequency ref-
erence.)
1: Enable (Continue operation at 80% of fre-
quency reference prior to loss.)
* Frequency reference loss: Frequency refer-
ence voltage drop of 90% within 400 ms.
0, 1
1
0
No
5-17
n065
0141
Multi-func-
tion analog
output type
selection
Selects the multi-function analog output type.
0: Analog voltage output (functions set in n066)
1: Pulse train output (functions set in n150)
0, 1
1
0
No
5-38
List of Parameters
Chapter 10
Summary of Contents for SYSDRIVE 3G3MV-A2001
Page 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Page 2: ......
Page 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Page 18: ......
Page 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Page 32: ......
Page 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 74: ......
Page 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 102: ......
Page 142: ......
Page 242: ......
Page 268: ......
Page 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 303: ...Chapter 10 List of Parameters 10...
Page 337: ...Chapter 11 Using the Inverter for a Motor 11...
Page 343: ......
Page 344: ...I527 E1 04...