![background image](http://html1.mh-extra.com/html/omron/sysdrive-3g3mv-a2001/sysdrive-3g3mv-a2001_user-manual_742837309.webp)
10-7
Param-
eter
No.
Ref-
er-
ence
page
Changes
during
opera-
tion
Default
setting
Unit
of
set-
ting
Set-
ting
range
Description
Name
Regis-
ter No.
(Hex)
n033
0121
Upper fre-
quency refer-
ence limit
Used to set the upper and lower fre-
quency reference limits in percentage
based on the maximum frequency as
100%.
* If n034 is set to a value less than
0 to
110
1%
100
No
5-12
n034
0122
Lower fre-
quency refer-
ence limit
If n034 is set to a value less than
the minimum output frequency
(n016), the Inverter will have no
output when a frequency reference
less than the minimum output fre-
quency input is input.
0 to
110
1%
0
No
5-12
n035
0123
Frequency
reference set-
ting/display
unit selection
Set the unit of frequency reference
and frequency-related values to be
set or monitored through the Digital
Operator.
0: 0.01 Hz
1: 0.1%
2 to 39: rpm (number of motor poles)
40 to 3,999: The value to be set or
monitored at max. frequency.
Set the value as shown below.
* To display 50.0, for example, set
the value to 1500. The setting unit
of each parameter or monitor item
below varies with the decimal
place.
•
Parameters: n024 through n032 and
n120 through n127
•
Monitor Items: U-01 and U-02
jjjj
Three digits
Decimal place (See
note below)
0 to
3,999
1
0
No
5-18
n036
0124
Rated motor
current
Used to set the rated motor current
for motor overload detection (OL1)
based on the rated motor current.
* In vector control mode, this param-
eter is used as a constant for vec-
tor control operation.
* Motor overload detection (OL1) is
disabled by setting the parameter
to 0.0.
* The rated motor current is default
to the standard rated current of the
maximum applicable motor.
0.0 to
150%
of rated
output
current
of the
Inverter
0.1 A
Varies
with the
capac-
ity
No
5-5
5-7
List of Parameters
Chapter 10
Summary of Contents for SYSDRIVE 3G3MV-A2001
Page 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Page 2: ......
Page 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Page 18: ......
Page 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Page 32: ......
Page 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 74: ......
Page 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 102: ......
Page 142: ......
Page 242: ......
Page 268: ......
Page 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 303: ...Chapter 10 List of Parameters 10...
Page 337: ...Chapter 11 Using the Inverter for a Motor 11...
Page 343: ......
Page 344: ...I527 E1 04...