Address <a>
Set the addresses of the Slaves.
Note
In this example, the Slave addresses are set in S + 2, S + 5, and S + 8. Therefore, retrieve the data
from those locations.
The address is set in the LSB of each word. To read the byte, select
Variable Reverse
, otherwise
the data will be read from the LSB. Then click on
Edit Variable
with the left button of the mouse.
Select
Read R ()
and set
Data/Address
to the operand (3N + 2) using the number (N) of times to
repeat the step.
Set
Edit Length
to 1 byte as a default. If the default value has been changed, set it to 0N + 1.
Data
Set the expected response in details.
•
Response to the RUN Command and Frequency Reference
The response to the DSR message written consists of the following items.
CRC-16 check (Set with <c>)
Number of write data registers: 2
Write start register number (RUN command: 0001)
Function code (Write 10)
Slave address (Set with <a>)
Set data: <a> + [10] + [00] + [01] + [00] + [02] + <c>
<a>
The Slave address is set in the address box. Insert the address with the
Insert
icon.
[10] + [00] + [01] + [00] + [02]
Set the constants contained in the response.
Use
Set Constant
and set the constants in Hex.
<c>
The check code is set in the check code box. Insert the check code by using the
Insert
icon. All the
data including the address data before the check code is used. Mark all the items if the Protocol
Support Tool is used. The check code is automatically set by the CX-Protocol.
•
Response to the Inverter Status Read
The response to the DSR message to request the Inverter status in register 002C Hex consists of the
following items.
CRC-16 check (Set with <c>)
Inverter status data (Set with variable)
Number of bytes of attached data (set with <l>)
Function code (Write 10)
Slave address (Set with <a>)
Set data: <a> + [03] + <I> + (W (1N + 1), 2) + <c>
<a., [03], <c>
The address data, constant data, and check code data are the same as the above.
Communications
Chapter 7
Summary of Contents for SYSDRIVE 3G3MV-A2001
Page 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Page 2: ......
Page 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Page 18: ......
Page 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Page 32: ......
Page 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 74: ......
Page 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 102: ......
Page 142: ......
Page 242: ......
Page 268: ......
Page 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 303: ...Chapter 10 List of Parameters 10...
Page 337: ...Chapter 11 Using the Inverter for a Motor 11...
Page 343: ......
Page 344: ...I527 E1 04...