10-27
Param-
eter
No.
Ref-
er-
ence
page
Changes
during
opera-
tion
Default
setting
Unit
of
set-
ting
Set-
ting
range
Description
Name
Regis-
ter No.
(Hex)
n134
0186
Integral (I)
upper limit
Sets the upper limit value of integral
control output.
Sets the parameter as a percentage
based on the maximum frequency as
100%.
0 to
100
1%
100
Yes
6-17
n135
0187
PID primary
delay time
Set this parameter to the primary
delay time constant for the frequency
reference after PID control.
* Normally, the default setting does
not need to be changed.
0.0 to
10.0
0.1 s
0.0
Yes
6-17
n136
0188
Feedback
loss detection
selection
Sets the detection method of feed-
back loss in PID control.
0: Feedback loss detection disabled.
1: Feedback loss detection enabled
(Nonfatal error: FbL warning)
2: Feedback loss detection enabled
(Fatal error: FbL fault)
0 to 2
1
0
No
6-17
n137
0189
Feedback
loss detection
level
Sets the detection level of feedback
loss.
Sets the parameter as a percentage
based on the feedback value equiva-
lent to the maximum frequency as
100%.
0 to
100
1%
0
No
6-18
n138
018A
Feedback
loss detection
time
Sets the detection time of feedback
loss.
* If the detection level set in n137 or
lower is detected for the set time in
n138, the result will be determined
as feedback loss.
0.0 to
25.5
0.1 s
1.0
No
6-18
n139
018B
Energy-sav-
ing control
selection
Select the energy-saving control func-
tion.
0: Disabled
1: Enabled
* This parameter is enabled in V/f
control mode only.
0, 1
1
0
No
6-6
n140
018C
Energy-sav-
ing control
coefficient K2
Sets the coefficient for the primary
level of energy-saving control.
* The constant automatically chan-
ges according to the motor code in
n158. Make fine adjustments of the
contact if necessary after setting
the motor code in n158.
0.0 to
6,550
0.1
Varies
with the
capac-
ity
No
6-7
n141
018D
Energy-sav-
ing voltage
lower limit at
60-Hz output
These parameters prevent the output
voltage of the Inverter from dropping
excessively so that the motor will not
stall or come to a stop at the primary
level of energy-saving control.
Sets the lower limit of output voltage
0 to
120
1%
50
No
6-8
n142
018E
Energy-sav-
ing voltage
lower limit at
6-Hz output
Sets the lower limit of output voltage
as a percentage at each frequency
based on the rated motor voltage as
100%.
* Normally, the default settings do
not need to be changed.
0 to 25
1%
12
No
6-8
List of Parameters
Chapter 10
Summary of Contents for SYSDRIVE 3G3MV-A2001
Page 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Page 2: ......
Page 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Page 18: ......
Page 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Page 32: ......
Page 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 74: ......
Page 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 102: ......
Page 142: ......
Page 242: ......
Page 268: ......
Page 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 303: ...Chapter 10 List of Parameters 10...
Page 337: ...Chapter 11 Using the Inverter for a Motor 11...
Page 343: ......
Page 344: ...I527 E1 04...