6-45
•
The value will be set in 0.01-Hz increments if the frequency is less than 100 Hz and 0.1-Hz increments
if the frequency is 100 Hz or over.
Frequency Detection Level 1
Output
frequency
Reset width –2 Hz
n095 (Frequency
detection level)
Time
Frequency
detection level 1
Time
Frequency Detection Level 2
Output
frequency
Reset width +2 Hz
n095 (Frequency
detection level)
Time
Frequency
detection level 2
Time
6-10-9 UP/DOWN Command Frequency Memory (n100)
•
This function changes the reference frequency by turning the UP and DOWN commands ON and OFF.
•
In order to use this function, set n056 for multi-function input 7 to 34. Then the multi-function input 6
(S6) and multi-function input 7 (S7) terminals are set as described below.
Multi-function input 6 (S6): UP command
Multi-function input 7 (S7): DOWN command
•
The output frequency held by the UP/DOWN function will be stored in the memory if n100 for UP/
DOWN frequency storage is set to 1.
•
By setting n100 to 1, the frequency reference kept on hold for 5 s or more will be retained even after a
power interruption, and operation will be restarted at this frequency the next time the RUN command is
input.
•
The stored output frequency will be cleared from the memory if n100 is set to 0. The retained frequency
is initialized if n001 for parameter initialization is set to 8 or 9.
Note
While this function is used, frequency references can only be used in remote mode with the UP/
DOWN command or inching frequency command. All multi-step speed references are disabled.
Advanced Operation
Chapter 6
Summary of Contents for SYSDRIVE 3G3MV-A2001
Page 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Page 2: ......
Page 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Page 18: ......
Page 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Page 32: ......
Page 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 74: ......
Page 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 102: ......
Page 142: ......
Page 242: ......
Page 268: ......
Page 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 303: ...Chapter 10 List of Parameters 10...
Page 337: ...Chapter 11 Using the Inverter for a Motor 11...
Page 343: ......
Page 344: ...I527 E1 04...