![background image](http://html1.mh-extra.com/html/omron/sysdrive-3g3mv-a2001/sysdrive-3g3mv-a2001_user-manual_742837141.webp)
5-39
Note 1.
Refer to the above information on the set values in n066 and set the multiplication rate based
on the reference value. For example, if 5-V output is desired at maximum output frequency
(with n066 set to 0), set n067 to 0.50.
Note 2.
The multi-function analog output terminals (AM and AC) have a maximum output of 10 V.
5-11-2 Setting the Pulse Monitor Output (n065 and n150)
•
By setting n065 for multi-function analog output type selection to 1 for pulse train output, monitoring
pulse output frequency signals is possible through the multi-function analog output terminals.
•
The relationship between the output frequency and pulse train output frequency is set in n150 for mul-
ti-function analog output, pulse train frequency selection.
n065
Multi-function Analog Output Type
Selection
Register
0141 Hex
Changes during
operation
No
Setting
range
0, 1
Unit of
setting
1
Default setting
0
Set Values
Value
Description
0
Analog voltage output (with monitoring item set in n066)
1
Pulse train output (according to output frequency set in n150)
n150
Multi-function Analog Output,
Pulse Train Frequency Selection
Register
0197 Hex
Changes during
operation
No
Setting
range
0, 1, 6, 12, 24, and 36
Unit of
setting
1
Default setting
0
Set Values
Value
Description
0
1,440 Hz at max. frequency (A proportional relationship is applied to frequencies less than
the maximum frequency)
1
1x output frequency
6
6x output frequency
12
12x output frequency
24
24x output frequency
36
36x output frequency
Note
The pulse train voltage is 10 V at high level and 0 V at low level at a duty rate of 50%.
Basic Operation
Chapter 5
Summary of Contents for SYSDRIVE 3G3MV-A2001
Page 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Page 2: ......
Page 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Page 18: ......
Page 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Page 32: ......
Page 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 74: ......
Page 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 102: ......
Page 142: ......
Page 242: ......
Page 268: ......
Page 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 303: ...Chapter 10 List of Parameters 10...
Page 337: ...Chapter 11 Using the Inverter for a Motor 11...
Page 343: ......
Page 344: ...I527 E1 04...