10-22
Para
me-
ter
No.
Reg-
ister
No.
(Hex)
Name
Description
Set-
ting
range
Unit
of
set-
ting
Defa
ult
set-
ting
Chan-
ges dur-
ing
opera-
tion
Ref-
er-
ence
page
n089
0159
DC injec-
tion brak-
ing current
Used to impose DC on the induction motor for
braking control.
Sets the DC braking current as a percentage
0 to
100
1%
50
No
6-26
n090
015A
DC injec-
tion brak-
ing-to-stop
time
Sets the DC braking current as a percentage
based on the rated current of the Inverter as
100%.
Output
frequency
0.0 to
25.5
0.1 s
0.5
No
6-26
n091
015B
Startup DC
injection
braking
time
frequency
Time
Minimum
output
frequency
(n016)
n091
n090
0.0 to
25.5
0.1 s
0.0
No
6-26
n092
015C
Stall pre-
vention
during
decelera-
tion
Used to select a function to change the decel-
eration time of the motor automatically so that
there will be no overvoltage imposed on the
motor during deceleration.
0: Stall prevention during deceleration enabled
1: Stall prevention during deceleration disabled
* Be sure to set the parameter to 1 when the
Braking Resistor Unit or a braking resistor is
used as an option.
0, 1
1
0
No
6-27
n093
015D
Stall pre-
vention
level dur-
ing accel-
eration
Used to select a function to stop the accelera-
tion of the motor automatically for stall preven-
tion during acceleration.
Sets the level as a percentage based on the
rated current of the Inverter as 100%.
30 to
200
1%
170
No
6-28
n094
015E
Stall pre-
vention
level dur-
ing opera-
tion
Used to select a function to reduce the output
frequency of the Inverter automatically for stall
prevention during operation.
Sets the level as a percentage based on the
rated current of the Inverter as 100%.
30 to
200
1%
160
No
6-29
n095
015F
Frequency
detection
level
Used to set the frequency to be detected.
* The parameter n059 for multi-function out-
put must be set for the output of frequency
detection levels 1 and 2.
0.00
to
400.0
0.01
Hz
0.00
No
6-44
n096
0160
Overtorque
detection
function
selection 1
Used to enable or disable overtorque detection
and select the processing method after over-
torque detection.
0: Overtorque detection disabled
1: Overtorque detection only when speed coin-
cides and operation continues (issues
alarm)
2: Overtorque detection only when speed coin-
cides and output turned OFF (for protection)
3: Overtorque always detected and operation
continues (issues alarm)
4: Overtorque always detected and output
turned OFF (for protection)
0 to 4
1
0
No
6-31
n097
0161
Overtorque
detection
function
selection 2
Select the item to detect overtorque.
0: Detected from output torque.
1: Detected from output current.
0, 1
1
0
No
6-32
List of Parameters
Chapter 10
Summary of Contents for SYSDRIVE 3G3MV-A2001
Page 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Page 2: ......
Page 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Page 18: ......
Page 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Page 32: ......
Page 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 74: ......
Page 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 102: ......
Page 142: ......
Page 242: ......
Page 268: ......
Page 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 303: ...Chapter 10 List of Parameters 10...
Page 337: ...Chapter 11 Using the Inverter for a Motor 11...
Page 343: ......
Page 344: ...I527 E1 04...