2-34
D
Braking Resistors and Braking Resistor Units for 200-V-class Inverters
Inverter
3G3MV-
Braking Resistor
(3% usage rate ED)
3G3IV-
Braking Resistor Unit
(10% usage rate ED)
3G3IV-
Minimum
connection
resistance
A2001/AB001
PERF150WJ401 (400
Ω
)
---
300
Ω
A2002/AB002
(
)
A2004/AB004
PERF150WJ201 (200
Ω
)
PLKEB20P7 (200
Ω
, 70 W)
200
Ω
A2007/AB007
(
)
(
,
)
120
Ω
A2015/AB015
PERF150WJ101 (100
Ω
)
PLKEB21P5 (100
Ω
, 260 W)
60
Ω
A2022/AB022
PERF150WJ700 (70
Ω
)
PLKEB22P2 (70
Ω
, 260 W)
A2037/AB037
PERF150WJ620 (62
Ω
)
PLKEB23P7 (40
Ω
, 390 W)
32
Ω
A2055
---
PLKEB25P5 (30
Ω
, 520 W)
9.6
Ω
A2075
---
PLKEB27P5 (30
Ω
, 780 W)
9.6
Ω
Note 1.
Do not use resistances less than than the minimum connection resistance value. Doing so
may damage the Inverter.
Note 2.
The usage rate is shown as a percentage of the braking time in one cycle. If one cycle is 10
seconds, for example, one second of braking is possible using a Braking Resistor Unit (10%
usage rate ED). If the usage rate is to be exceeded, a detailed regeneration energy calcula-
tion will be required.
D
Braking Resistors and Braking Resistor Units for 400-V-class Inverters
Inverter
3G3MV-
Braking Resistor
(3% usage rate ED)
3G3IV-
Braking Resistor Unit
(10% usage rate ED)
3G3IV-
Minimum
connection
resistance
A4002
PERF150WJ751 (750
Ω
)
PLKEB40P7 (750
Ω
, 70 W)
750
Ω
A4004
(
)
(
,
)
A4007
510
Ω
A4015
PERF150WJ401 (400
Ω
)
PLKEB41P5 (400
Ω
, 260 W)
240
Ω
A4022
PERF150WJ301 (300
Ω
)
PLKEB42P2 (250
Ω
, 260 W)
200
Ω
A4037
PERF150WJ401 (400
Ω
)
×
2
PLKEB43P7 (150
Ω
, 390 W)
100
Ω
A4055
---
PLKEB45P5 (100
Ω
, 520 W)
32
Ω
A4075
---
PLKEB47P5 (75
Ω
, 780 W)
32
Ω
Note 1.
Do not use resistances less than than the minimum connection resistance value. Doing so
may damage the Inverter.
Note 2.
The usage rate shows the braking time as a percentage of one cycle. If a cycle is 10 seconds,
for example, one second of braking is possible using a Braking Resistor Unit (10% usage rate
ED). If the usage rate is to be exceeded, a detailed regeneration energy calculation will be
required.
2-2-4 Wiring Control Circuit Terminals
A control signal line must be 50 m maximum and separated from power lines.
The frequency reference must be input into the Inverter through shielded, twisted-pair
wires.
H
Wiring Control I/O Terminals
Wire each control I/O terminal under the following conditions.
Design
Chapter 2
Summary of Contents for SYSDRIVE 3G3MV-A2001
Page 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Page 2: ......
Page 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Page 18: ......
Page 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Page 32: ......
Page 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 74: ......
Page 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 102: ......
Page 142: ......
Page 242: ......
Page 268: ......
Page 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 303: ...Chapter 10 List of Parameters 10...
Page 337: ...Chapter 11 Using the Inverter for a Motor 11...
Page 343: ......
Page 344: ...I527 E1 04...