This parameter setting is to select whether or not to detect Digital Operator connection errors.
n010
Operation Selection at Digital
Operator Interruption
Register
010A Hex
Changes during
operation
No
Setting
range
0, 1
Unit of
setting
1
Default setting
0
Set Values
Value
Description
0
The Digital Operator connection error is not detected (Nonfatal error)
1
The Digital Operator connection error is detected (Error output and the Inverter coasts to a
stop)
6-10-2 Motor Protection Functions (n037 and n038)
•
This parameter setting is for motor overload detection (OL1).
n037
Motor Protection Characteristics
Register
0125 Hex
Changes during
operation
No
Setting
range
0 to 2
Unit of
setting
1
Default setting
0
Set Values
Value
Description
0
Protection characteristics for general-purpose induction motors
1
Protection characteristics for Inverter-dedicated motors
2
No protection
•
This parameter is used to set the electric thermal characteristics of the motor to be connected.
•
Set the parameter according to the motor.
•
If a single Inverter is connected to more than one motor, set the parameter to 2 for no protection. The
parameter is also disabled by setting n036 for rated motor current to 0.0. Provide overload protection
for each motor by setting up, for example, thermal relays.
n038
Motor Protection Time
Register
0126 Hex
Changes during
operation
No
Setting
range
1 to 60 (min)
Unit of
setting
1 min
Default setting
8
Advanced Operation
Chapter 6
Summary of Contents for SYSDRIVE 3G3MV-A2001
Page 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Page 2: ......
Page 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Page 18: ......
Page 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Page 32: ......
Page 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 74: ......
Page 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 102: ......
Page 142: ......
Page 242: ......
Page 268: ......
Page 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 303: ...Chapter 10 List of Parameters 10...
Page 337: ...Chapter 11 Using the Inverter for a Motor 11...
Page 343: ......
Page 344: ...I527 E1 04...