5-37
Value
Description
Function
8
Undertorque being
monitored (NO-contact
output)
Output if any of the following parameter conditions is satisfied.
•
Undertorque detection function selection (n117)
•
Undertorque detection level (n118)
O
t
d t
ti
f
ti
l
ti
2 ( 097)
9
Undertorque being
monitored (NC-contact
output)
•
Overtorque detection function selection 2 (n097)
•
Undertorque detection time (n119)
Note
NO contact: ON with undertorque being detected, NC contact:
OFF with undertorque being detected
10
Warning output
ON: Warning being detected (Nonfatal error being detected)
11
Base block in progress
ON: Base block in progress (in operation with output turned OFF)
12
RUN mode
ON: Local mode (with the Digital Operator)
13
Inverter ready
ON: Inverter ready to operate (with no fault detected)
14
Fault retry
ON: Fault retry (Inverter resetting with fault retry (n082) not set to 0)
15
UV in progress
ON: Undervoltage being monitored (main circuit undervoltage UV1
detected)
16
Rotating in reverse
direction
ON: Rotating in reverse direction
17
Speed search in progress
ON: Speed search in progress
18
Communications output
ON: Communications output (turns ON/OFF according to 0009 Hex
set from communications. Communications setting = ON)
19
PID feedback loss
ON: PID feedback being lost (set detection method in n136, n137,
n138)
20 (See
note 2.)
Frequency reference loss
ON: Frequency reference lost. (When the frequency reference loss
detection (n064) is enabled, and the frequency reference selection
(n004) is set for analog input or pulse train input.)
21 (See
note 2.)
Inverter overheating
warning oH3
ON: Inverter overheating warning
ON while the Inverter overheating warning signal is being input
(while oH3 is flashing).
Note 1.
Use “during RUN” (set value: 1) or “zero speed“ (set value: 3) for the timing for stopping the
motor using a brake. To specify a precise stop timing, set “frequency detection 1” (set value: 4)
or “frequency detection 2” (set value: 5), and set the frequency detection level (n095).
Note 2.
Set values 20 (frequency reference loss) and 21 (Inverter overheating warning oH3) are avail-
able for 5.5- and 7.5-kW Inverters only.
Basic Operation
Chapter 5
Summary of Contents for SYSDRIVE 3G3MV-A2001
Page 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Page 2: ......
Page 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Page 18: ......
Page 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Page 32: ......
Page 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 74: ......
Page 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 102: ......
Page 142: ......
Page 242: ......
Page 268: ......
Page 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 303: ...Chapter 10 List of Parameters 10...
Page 337: ...Chapter 11 Using the Inverter for a Motor 11...
Page 343: ......
Page 344: ...I527 E1 04...