5-21
relationship between multi-step speed references 1 through 4 and frequency references 1
through 16.
Frequency reference
Multi-step speed
reference 1
(Set value: 6)
Multi-step speed
reference 2
(Set value: 7)
Multi-step speed
reference 3
(Set value: 8)
Multi-step speed
reference 4
(Set value: 9)
Frequency reference 1
OFF
OFF
OFF
OFF
Frequency reference 2
ON
OFF
OFF
OFF
Frequency reference 3
OFF
ON
OFF
OFF
Frequency reference 4
ON
ON
OFF
OFF
Frequency reference 5
OFF
OFF
ON
OFF
Frequency reference 6
ON
OFF
ON
OFF
Frequency reference 7
OFF
ON
ON
OFF
Frequency reference 8
ON
ON
ON
OFF
Frequency reference 9
OFF
OFF
OFF
ON
Frequency reference 10
ON
OFF
OFF
ON
Frequency reference 11
OFF
ON
OFF
ON
Frequency reference 12
ON
ON
OFF
ON
Frequency reference 13
OFF
OFF
ON
ON
Frequency reference 14
ON
OFF
ON
ON
Frequency reference 15
OFF
ON
ON
ON
Frequency reference 16
ON
ON
ON
ON
To change the frequency of frequency reference 2, for example, turn ON only the multi-function input
terminal where multi-step speed reference 2 is set, and turn OFF any other multi-function input terminal.
For example, no settings for multi-step speed reference 3 or 4 will be required if only frequency refer-
ences 1 through 4 are used. Any multi-step speed reference not set is regarded as turned-OFF input.
D
Setting the Inching Frequency Command (n032)
•
The inching frequency command must be set as multi-function input in order to use the inching fre-
quency command.
n032
Inching Frequency Command
Register
0120 Hex
Changes during
operation
Yes
Setting
range
0.00 to max. frequency
Unit of
setting
0.01 Hz
(See note
1.)
Default setting
6.0
Note 1.
The setting unit of the inching frequency command is changed with the set value in n035 for
frequency reference setting and decimal place selection. The value will be set in 0.01-Hz
increments if the frequency is less than 100 Hz and 0.1-Hz increments if the frequency is 100
Hz or over.
Note 2.
In order to use the inching frequency command, one of the n050 through n056 parameters for
multi-function input must be set to 10 as an inching frequency command. Parameter n032 is
selectable by turning ON the multi-function input set with the inching frequency command.
The inching frequency command takes precedence over the multi-step speed reference (i.e.,
when the inching frequency command is ON, all multi-step speed reference input will be
ignored).
Basic Operation
Chapter 5
Summary of Contents for SYSDRIVE 3G3MV-A2001
Page 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Page 2: ......
Page 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Page 18: ......
Page 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Page 32: ......
Page 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 74: ......
Page 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 102: ......
Page 142: ......
Page 242: ......
Page 268: ......
Page 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 303: ...Chapter 10 List of Parameters 10...
Page 337: ...Chapter 11 Using the Inverter for a Motor 11...
Page 343: ......
Page 344: ...I527 E1 04...