![background image](http://html1.mh-extra.com/html/omron/sysdrive-3g3mv-a2001/sysdrive-3g3mv-a2001_user-manual_742837106.webp)
5-4
Parameter
Name
Default value
V/f control
(Set value: 0)
Vector control
(Set value: 1)
n014
Middle output frequency
1.5 Hz
3.0 Hz
n015
Middle output frequency voltage
12.0 V (24.0 V)
(See note 2.)
11.0 V (22.0 V)
n016
Minimum output frequency
1.5 Hz
1.0 Hz
n017
Minimum output frequency voltage
12.0 V (24.0 V)
(See note 2.)
4.3 V (8.6 V)
n104
Torque compensation primary-delay
time constant
0.3 s
0.2 s
n111
Slip compensation gain
0.0
1.0
n112
Slip compensation primary-delay
time constant
2.0 s
0.2 s
Note 1.
Values in parentheses are for 400-V models.
Note 2.
For 5.5- and 7.5-kW Inverters, this value is set to 10.0 V for 200-V-class models and to 20.0 V
for 400-V-class models.
Basic Operation
Chapter 5
Summary of Contents for SYSDRIVE 3G3MV-A2001
Page 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Page 2: ......
Page 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Page 18: ......
Page 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Page 32: ......
Page 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 74: ......
Page 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 102: ......
Page 142: ......
Page 242: ......
Page 268: ......
Page 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 303: ...Chapter 10 List of Parameters 10...
Page 337: ...Chapter 11 Using the Inverter for a Motor 11...
Page 343: ......
Page 344: ...I527 E1 04...