background image

SMA

Quick Guide

 

 

V1.0

Series AC Drive

Professional AC Drive Manufacturer

Electronic instruction

Summary of Contents for SMA Series

Page 1: ...SMA Quick Guide V1 0 Series AC Drive Professional AC Drive Manufacturer Electronic instruction...

Page 2: ...If the charging indicator doesn t go out after the AC power is cut off it means that there is still high voltage in the AC drive which is very dangerous and do not touch the internal circuit and compo...

Page 3: ...g method Encoder setting Simulation setting method External voltage 0 5V 0 10V Other functions The lower frequency limit starting frequency stopping frequency general control Acceleration and decelera...

Page 4: ...voltage by the voltage regulator This product must be placed in the packing box before installa tion If not for use please pay attention to the following items when storing It must be placed in a dus...

Page 5: ...ve If installing it on the loose surface the stress may cause the damage of the main circuit parts and the AC drive will be damaged The wall for installation should use the non flammable materials suc...

Page 6: ...23A SMA0D75G43A SMA01D5G43A SMA02D2G43A 0 4 0 75 1 5 0 75 1 5 2 2 2 1 3 8 7 0 3 4 4 8 6 2 0 4 0 75 1 5 0 75 1 5 2 2 Farme SMA10 SMA04D0G23A SMA02D2G23A 2 2 4 0 9 0 17 0 2 2 4 0 SMA20 SMA10 SMA04D0G43A...

Page 7: ...hase sharing optional two terminals access for single phase Output terminal of the AC drive Connection terminal of brake resistance DB Braking Unit R S T R S T DB U V W U V W M S1 S2 S3 S4 S5 S6 Forwa...

Page 8: ...ace Positive rotation Negative rotation Coast to stop Multi speed SS1 Multi speed SS2 DA DB Multi speed SS4 Y2 Y1A Y1B Y1C AC drive grounding Input voltage Input voltage Voltage and current switching...

Page 9: ...rminal AI1 control 2 Terminal AI2 control 3 RS485 control P0 02 Source of frequency command 0 P0 03 The maximum frequency 50 0Hz P0 04 Acceleration time 10 0s 5 0 800Hz The maximum frequency of AC dri...

Page 10: ...nt exceeds this value the AC drive will be protected 000BH P0 12 Monitoring selection 2 6 2 output frequency outpout current outpot voltage 3 output frequency output current output voltage DC voltage...

Page 11: ...rque curve 4 2 0 power down torque curve Function Code Parameter Name Setting Range Default Address Multi point V F frequency F2 Multi point V F voltage V2 Multi point V F frequency F3 Multi point V F...

Page 12: ...external analog input adjusted as a per centage AI1 gain P2 06 1 P2 07 2 P2 08 3 Y1 function Y2 function Reserved 0 4 0 NO function 1 Fault 2 Running 3 Frequency reached 4 Frequency upper limit reach...

Page 13: ...AI1 input value 13 AI2 input value 14 Reserved 15 Reserved 16 Internal temperature 17 Reserved 18 Reserved 19 Communication set value 020DH 020EH 020FH 0210H P2 18 A01 output gain 100 0 P2 22 Reserve...

Page 14: ...ffer DC motor braking vol tage when starting and stop ping By adjusting this par ameter different braking voltages can be obtained When adjusting this parame ter it must increase slowly from small val...

Page 15: ...aking resistor is adjusted by percentage P4 Fault and protection parameters group P4 00 Motor overload protection 0 0 2 0 No overload protection 1 Normal motor overload protection 2 AC drive overload...

Page 16: ...ault current 0406H 0407H 0408H 0409H 040AH 040BH 040CH 040DH P4 14 NC Read only Output frequency value of the latest fault Fault frequency P5 PID control parameters group P5 00 PID control selection 0...

Page 17: ...ion of wake up P6 Communication control function parameter group P6 00 Address 1 P6 01 Baud rate selection 3 1 247 0 7 0 1200bps 1 2400bps 2 4800bps 3 9600bps 4 19200bps 5 38400bps 6 57600bps 7 115200...

Page 18: ...uency 4 Multi frequency 5 Multi frequency 6 Multi frequency 7 P7 06 Multi frequency 8 Function Code Parameter Name Setting Range PU Monitoring parameter group Function Code Parameter Name Setting Rang...

Page 19: ...ive running status PU 28 Maximum current value PU 29 Maximum EDC PU 30 Maximum temperature PU 31 Minimum EDC PU 32 AC drive power level PU 33 AC drive rated voltage PU 34 AC drive rated current PU 35...

Page 20: ...allowable value Error setting of the maximum and in termediate value of frequency or volt age Note 1 Note 1 for example if the intermediate frequency is set greater than the maximum frequency it will...

Page 21: ...overcurrent 4 OC3 Deceleration overcurrent 5 OU1 Acceleration overvoltage 6 OU2 Constant speed overvoltage 7 OU3 Deceleration overvoltage 8 LU Undervoltage 9 OL1 AC drive overload 10 OL2 Motor overlo...

Page 22: ...21 9 Warranty Service...

Page 23: ...nge without notice Professional AC Drive Manufacturer ZHEJIANG EACN ELECTRONIC TECHNOLOGY CO LTD Address No 1 Jinhe Road Qinshan Street Haiyan County Jiaxing City Zhejiang Province Website www eacn cn...