![background image](http://html1.mh-extra.com/html/omron/omnuc-g5/omnuc-g5_user-manual_742230462.webp)
9-31
9-4 Setting the Mode
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
9
Operation
7. Returning to PARAMETER WRITE mode
8. Restart the power supply to the driver.
Precautions for Correct Use
The items that are limited depend on the mode.
If the Front Panel Parameter Write Selection (Pn617) is set to 1, the parameter set value is
automatically written to EEPROM when changed.
Refer to the Front Key Protection Setting (Pn535) in "8-6 Extended Parameters" (P.8-46) for
details on the front panel lock function.
Writing will start. (This display will appear only momentarily.)
This indicates a normal completion. In addition to this display,
either
or
may
be
displayed.
If
is displayed, writing has been completed normally,
but some of the changed parameters will be valid only after the
power supply has been turned OFF and ON again. Turn OFF the
driver power supply and then turn it ON again.
will be displayed if there is a write error. Write the
data again.
Key
operation
Display example
Explanation
Key
operation
Display example
Explanation
Press the
key to return to PARAMETER WRITE mode.