6-8 Torque Limit
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
6
Applied Functions
Torque Limit in Position, Speed and Full Closing Controls
For the torque limit in torque control, always select No. 1 Torque Limit (Pn013).
The torque limit under torque feed-forward selection is enable only during speed control when the
set value is 1 to 3.
Pn521 set
value
Explanation
0
Forward operation: Set by PCL (0 to 10 V)
Reverse operation: Set by NCL (
−
10 to 0 V)
1
Limit in both forward and reverse operation: Set by Pn013
2
Forward operation: Set by Pn013
Reverse operation: Set by Pn522
3
Switch the limit value using torque limit switching (TLSEL).
When TLSEL is OFF
Limit in both forward and reverse operation: Pn013
When TLSEL is ON
Limit in both forward and reverse operation: Pn522
4
Forward operation: Set by PCL (0 to 10 V)
Reverse operation: Set by NCL (0 to 10 V)
5
Limit in both forward and reverse operation: Set by PCL (0 to 10 V)
6
Switch the limit value using torque limit switching (TLSEL).
When TLSEL is OFF
Forward operation: Pn013
Reverse operation: Pn522
When TLSEL is ON
Forward operation: Pn525
Reverse operation: Pn526