![background image](http://html.mh-extra.com/html/omron/omnuc-g5/omnuc-g5_user-manual_742230319.webp)
6
6-19
6-6 Brake Interlock
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Applied Functions
Operation
Servo ON/OFF Operation Timings
<
when Motor Is Stopped
>
*1. The servo will not turn ON until the motor rotation speed drops to approx. 30 r/min or below.
*2. The dynamic brake operation when the servo is OFF depends on Stop Selection with Servo OFF (Pn506).
*3. The brake interlock (BKIR) signal is output upon a release request from servo control. The BKIR signal is allocated
to a CN1 general-purpose output to be used.
Note:The brake attraction time and release time vary depending on the Servomotor brake. For details, refer to "3-3
Motor Specifications" (P.3-54).
Operation command (RUN)
ON
OFF
Dynamic brake relay
ON
OFF
Motor power supply
ON
OFF
Brake release request
from servo control *3
ON
OFF
Approx. 2 ms
Approx. 4 ms
1 to 6 ms
Approx. 60 ms
Brake interlock
output (BKIR) *3
ON
OFF
Released
Held
Attraction time
Release time
Servo OFF
Servo OFF
Servo ON
*
1
DB engaged
DB engaged
*2
DB Released
Power supply
No power supply
No power supply
Pn437
Release request
Release request
Holding brake operation
Brake released