8-53
8-6 Extended Parameters
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
8
Parameters Details
Explanation of Set Values
Select the signal confirmation time for alarm reset input signal (RESET).
Explanation of Set Values
When set to 1 or 2, the minimum time width will be as follows.
When set to 3 or 4, the minimum time width will be as follows.
Explanation of Set Values
Enable or disable the pulse prohibition input signal (IPG).
When command pulse prohibition input is enabled, command pulse input count process is force stopped.
Pn516
Alarm Reset Condition Selection
Setting
range
0 to 1
Unit
−
Default
setting
Power OFF
and ON
−
All
Set value
Explanation
0
120 ms
1
Follow the Control Input Signal Read Setting (Pn515).
Pn517
Error Counter Reset Condition Selection
Setting
range
0 to 4
Unit
−
Default
setting
1
Power OFF
and ON
−
Position Full closing
Set value
Explanation
0
Disabled
1
Clears the error counter at level when the signal is shorted for 500
μ
s or longer.
2
Clears the error counter at level when the signal is shorted for 1 ms or longer.
3
Clears the error counter at edge when the signal changes from open to shorted for 100
μ
s or longer.
4
Clears the error counter at edge when the signal changes from open to shorted for 1 ms or longer.
Set value 2: 1 ms or more
Error reset keeps repeating.
Set value 1: 500
μ
s or more
Error counter
reset input signal
Error is reset once.
Error counter
reset input signal
Set value 4: 1 ms or more
Set value 3: 100
μ
s or more
Pn518
Command Pulse Prohibition Input Setting
Setting
range
0 to 1
Unit
−
Default
setting
1
Power OFF
and ON
−
Position Full closing
Set value
Explanation
0
Enabled
1
Disabled