![background image](http://html.mh-extra.com/html/omron/omnuc-g5/omnuc-g5_user-manual_742230400.webp)
8-35
8-4 Analog Control Parameters
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
8
Parameters Details
The feedback pulse error is reset every time the motor rotates for the amount set by the Internal/
External Feedback Pulse Error Counter Reset (Pn329). This can be used for purposes where
feedback pulse error accumulates due to slippage.
When using feedback pulse error reset, make sure the feedback pulse error reset setting is set to
a proper value. In the case of an extremely small value, it may not function as a protection against
error operations caused by erroneous connection of external scale.
Take sufficient care to ensure safety.
Pn329
Internal/External Feedback Pulse Error Counter Reset
Setting
range
0 to 100
Unit
Rotation
Default
setting
Power OFF
and ON
Yes
Full closing
Feedback pulse
error value [command unit]
(absolute value)
Excessive
feedback pulse
error setting
Occurrence of excessive
feedback pulse
deviation error
Motor rotation
speed [rotation]
Feedback pulse error reset setting