4-42
4-4 Regenerative Energy Absorption
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
4
System Design
Combining External Regeneration Resistors
*1. Select a combination that has an absorption capacity greater than the average regeneration power (Pr).
*2. Do not use a combination with resistance values lower than the minimum external regeneration resistance of each driver. For
information on the minimum external regeneration resistance, refer to "Driver Regeneration Absorption Capacity"(P.4-39).
Safty Points
Surface temperatures on regeneration resistance can reach 200
°
C.
Do not place objects that tend to catch fire nearby. To prevent people from touching them, install
a type of cover that enables heat dissipation.
Regeneration
absorption
capacity
*
1
20 W
40 W
70 W
140 W
Model
R88A-RR08050S
R88A-RR080100S
R88A-RR08050S
R88A-RR080100S
R88A-RR22047S
R88A-RR22047S
Resistance
value
*
2
50
Ω
/100
Ω
25
Ω
/50
Ω
47
Ω
94
Ω
Connectio
n method
R
R
R
R
R
R
R
R
Regeneration
absorption capacity
*
1
140 W
280 W
560 W
Model
R88A-RR22047S
R88A-RR22047S
R88A-RR22047S
Resistance value
*
2
23.5
Ω
47
Ω
23.5
Ω
Connection
method
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
Regeneration
absorption capacity
*
1
180 W
360 W
1440 W
Model
R88A-RR50020S
R88A-RR50020S
R88A-RR50020S
Resistance value
*
2
20
Ω
10
Ω
10
Ω
Connection
method
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R