6
6-31
6-8 Torque Limit
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Applied Functions
6-8 Torque Limit
Outline of Operation
The output torque by the Servomotor can be limited.
This function is used in the following conditions.
• When push-motion operation, such as pressing, is performed.
• When the torque at startup and during deceleration should be suppressed to protect the
mechanical system, etc.
Various methods are available according to Torque Control Selection (Pn521).
Parameters Requiring Settings
Parameter
number
Parameter name
Explanation
Reference
Pn521
Torque Limit Selection
Select the torque limit based on the various
parameters and input signals.
Pn013
No. 1 Torque Limit
Set the No. 1 motor output torque limit value.
Pn522
No. 2 Torque Limit
Set the No. 2 motor output torque limit value.
Pn523
Torque Limit Switching
Setting 1
Set the rate of change (fluctuate) when switching
from the No. 1 torque limit to No. 2 torque limit.
Pn524
Torque Limit Switching
Setting 2
Set the rate of change (fluctuate) when switching
from the No. 2 torque limit to No. 1 torque limit.
Pn525
Forward External Torque
Limit
Set the forward torque limit using a network signal.
Pn526
Reverse External Torque
Limit
Set the reverse torque limit using a network signal.
Pn527
Analog Torque Limit Scale
Set the No. 2 motor output torque limit value.
Pn425
Analog Input 2 Offset
Set the offset adjustment value for the voltage
applied to analog input 2.
Pn426
Analog Input 2 Filter Time
Constant
Set the time constant of the first-order lag filter for
the voltage applied to analog input 2.
Pn428
Analog Input 3 Offset
Set the offset adjustment value for the voltage
applied to analog input 3.
Pn429
Analog Input 3 Filter Time
Constant
Set the time constant of the first-order lag filter for
the voltage applied to analog input 3.