![background image](http://html.mh-extra.com/html/omron/omnuc-g5/omnuc-g5_user-manual_742230132.webp)
3-49
3-1 Driver Specifications
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
3
Specifications
Monitor Connector Specifications (CN5)
Monitor Output Signals List
Monitor output (CN5)
Connectors for CN5 (Pin 6)
Monitor output circuit
Pin
Number
Symb
ol
Name
Function and interface
1
AM1
Analog monitor output 1
Outputs the analog signal for the monitor.
Default setting: Motor rotation speed 1 V/(1,000 r/min)
You can use Pn416 and Pn417 to change the item and
unit.
You can use Pn421 to change the output method.
2
AM2
Analog monitor output 2
Outputs the analog signal for the monitor.
Default setting: Motor rotation speed 1 V/(1,000 r/min)
You can use Pn418 and Pn419 to change the item and
unit.
You can use Pn421 to change the output method.
3
GND
Analog monitor ground
Ground for analog monitors 1, 2
4
−
Not used
Do not connect.
5
−
Not used
Do not connect.
6
−
Not used
Do not connect.
Name
Model
Manufacturer
Connector housing
51004-0600
Molex Japan
Connector terminal
50011-8000
Molex Japan
Servo Drive
Monitor equipment
3 GND
1/2 AM1/AM2
1 k