8-43
8-5 Interface Monitor Setting Parameters
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
8
Parameters Details
When speed command and motor speed are identical, speed conformity output signal is output.
This setting has a hysteresis of 10 r/min for detection.
Speed reached output signal is output when the motor speed reaches the speed set as the
achieved speed.
This setting has a hysteresis of 10 r/min for detection.
Pn435
Speed Conformity Detection Width
Setting
range
10 to 20,000
Unit
r/min
Default
setting
Power OFF
and ON
−
Speed
Speed [r/min]
A speed command after the acceleration
/deceleration processing
Speed command
Motor speed
Pn435
ON
ON
OFF
OFF
Pn435
Speed Conformity
Detection Range
Pn435
Speed Conformity Detection Range
Speed Conformity Detection Range
Time
Speed conformity
output
Pn436
Rotation Speed for Motor Rotation Detection
Setting
range
10 to 20,000
Unit
r/min
Default
setting
Power OFF
and ON
−
Speed
Speed [r/min]
Motor speed
Time
Pn436
+
10
Speed reached
output
Pn436
−
10
−
(Pn436
−
10)
−
(Pn436
+
10)
OFF
OFF
ON
ON