Contact a: Disabled (OFF) when signal input is open with COM
−
Enabled (ON) when signal input is shorted with COM
−
Contact b: Disabled (OFF) when signal input is shorted with COM
−
Enabled (ON) when signal input is open with COM
−
"
−
" indicates the status where no function is allocated.
Parameters that Can Be Allocated
Use the following parameters when changing the input signal allocation to use.
For the setting method, refer to "Input Signal Allocation Method".
Input Signal Allocation Method
Input the setting for each CONTROL mode in any of the parameters of Pn400 to Pn409 to
allocate signals.
Set the parameters based on the hex display standard.
Set the set value of the function for each CONTROL mode in "**" below.
Refer to the function number table provided below for the set value of each function. Logic
setting is included in the function numbers.
Example:
Position control or full closing control: Electronic gear switching input 1 for contact a (0Ch)
Speed control:
Internally set speed selection 1 for contact b (8Eh)
Torque control:
Disabled (00h)
This will be 36364 since the front panel display is in decimal numbers.
Parameter
number
Parameter name
Explanation
Reference
Pn400
Input Signal Selection 1
Set the SI1 input function allocation. This
parameter is based on the hex display
standard.(Take note that the display on the
front panel is based on the decimal display.)
Pn401
Input Signal Selection 2 Set the SI2 input function allocation.
Pn402
Input Signal Selection 3 Set the SI3 input function allocation.
Pn403
Input Signal Selection 4 Set the SI4 input function allocation.
Pn404
Input Signal Selection 5 Set the SI5 input function allocation.
Pn405
Input Signal Selection 6 Set the SI6 input function allocation.
Pn406
Input Signal Selection 7 Set the SI7 input function allocation.
Pn407
Input Signal Selection 8 Set the SI8 input function allocation.
Pn408
Input Signal Selection 9 Set the SI9 input function allocation.
Pn409
Input Signal Selection 10 Set the SI10 input function allocation.
00******h
Position control/full closing control
Speed control
Torque control
00008E0Ch
Position control/full closing control
Speed control
Torque control