![background image](http://html1.mh-extra.com/html/omron/omnuc-g5/omnuc-g5_user-manual_742230452.webp)
9-21
9-4 Setting the Mode
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
9
Operation
Safety Status Temperature
+
Dot information
...Input photocoupler OFF
SAFEty
SrVoFF
SrVon
ALArM
Servo ready
OFF: The dot is not lit.
ON: The dot is lit.
Flash display
Status that allows
normal changes
: Safety status
: Servo OFF
: Servo ON
: Alarm status
...Input photocoupler OFF
Press to switch between monitors you want to display.
...Output photocoupler OFF
...Input photocoupler ON
...Input photocoupler ON
...Output photocoupler ON