![background image](http://html.mh-extra.com/html/omron/omnuc-g5/omnuc-g5_user-manual_742230285.webp)
5-18
5-4 Internally Set Speed Control
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
5
BASIC CONTROL Mode
Selecting the Internally Set Speeds
The following tables show the internally set speeds that are set with VSEL1, VSEL2 and
VSEL3 (internally set speed selection 1, 2 and 3).
Pn300 = 1
Pn300 = 2
*1. The mode will be analog speed control.
Input the proper current to REF.
Pn300 = 3
Number
VSEL1
VSEL2
VSEL3
Set speed
0
OFF
OFF
Disabled
Pn304
1
ON
OFF
Disabled
Pn305
2
OFF
ON
Disabled
Pn306
3
ON
ON
Disabled
Pn307
Number
VSEL1
VSEL2
VSEL3
Set speed
0
OFF
OFF
Disabled
Pn304
1
ON
OFF
Disabled
Pn305
2
OFF
ON
Disabled
Pn306
3
ON
ON
Disabled
*1
Number
VSEL1
VSEL2
VSEL3
Set speed
0
OFF
OFF
OFF
Pn304
1
ON
OFF
OFF
Pn305
2
OFF
ON
OFF
Pn306
3
ON
ON
OFF
Pn307
4
OFF
OFF
ON
Pn308
5
ON
OFF
ON
Pn309
6
OFF
ON
ON
Pn310
7
ON
ON
ON
Pn311