background image

USER GUIDE

RESERVOIR

EK-Quantum 

Kinetic FLT 80 D5/DDC Body

Summary of Contents for Kinetic FLT 80 D5/DDC Body

Page 1: ...USER GUIDE RESERVOIR EK Quantum Kinetic FLT 80 D5 DDC Body ...

Page 2: ...he installation process The EK fittings require only a small amount of force to screw them firmly in place since the liquid seal is ensured by the rubber o ring gaskets The use of corrosion inhibiting coolants is always recommended for any liquid cooling system EKWB recommends any of the EK Cryofuel for worry free usage ...

Page 3: ... THE RESERVOIR 8 DDC PUMP VERSION 9 ATTACHING THE DDC PUMP ON TO THE RESERVOIR 9 INSTALLING EK QUANTUM KINETIC FLT WITH SUPPLIED MOUNTS 10 INSTALLING EK QUANTUM KINETIC FLT USING UNI PUMP BRACKET 12 ATTACHING EK QUANTUM KINETIC FLT WITH SUPPLIED MOUNTS 12 ATTACHING THE FITTINGS 14 CONNECTING THE D RGB LED STRIP 15 TESTING THE LOOP 15 SUPPORT AND SERVICE 16 SOCIAL MEDIA 16 ...

Page 4: ...cs DDC Mount 2 pcs D5 Mount 2 pcs Allen Key 2 5 mm 1 pc M4 x 10 DIN7984 Screw 4 pcs M4 x 25 DIN7984 Screw 4 pcs M4 x 8 DIN7984 Screw 4 pcs EK Quantum Kinetic FLT 80 D5 DDC Body PVC Washer M4 4 pcs Mounting Mechanism You may not need every screw from this package EAN 102171 ...

Page 5: ... 5 RESERVOIR DIMENSIONS 80 mm 120 mm 20 mm 45 mm 73 mm 101 mm 52 mm 36 mm 14 5 mm 17 mm 45 mm 73 mm 101 mm ...

Page 6: ... 16 7991DIN Screw 5 3 103116 EK Plug G1 4 7 4 103773 Alu cover Black 1 5 100199 D RGB LED Strip 1 6 103989 Top plexi plate 1 7 5092 OR 12 x 1 5 1 8 101921 OR 88 x 2 1 9 103772 Bottom plexi plate 1 10 102214 M4 x 30 DIN7991 Screw 3 11 101803 Pump holder 1 12 8311 M4 x 20 DIN7984 Screw 4 1 12 4 8 7 10 2 3 5 6 9 11 ...

Page 7: ... 7 GENERAL INFORMATIONS FLT Reservoir can be mount in multiple directions Vertically and horizontally position is optional Do not mount FLT Reservoir when the pump is in dead position ...

Page 8: ...der for later use STEP 2 Make sure that the gasket o ring is placed into the groove STEP 3 Carefully attach the D5 Pump and Pump Holder as shown on the photo After that secure all the parts together with M4 x 20 DIN 7984 Screws Tighten the screws using enclosed 2 5 mm Allen Key STEP 1 STEP 2 STEP 3 PUMP HOLDER 52 x 3 GASKET M4 x 20 DIN7984 M4 x 20 DIN7984 ...

Page 9: ...llen Key STEP 2 Carefully attach the DDC pump and make sure that gasket 46 x 2 5 is placed correctly Sealing gasket is included in additional bag Secure the pump with four 4 M4 x 25 7984DIN screws see sample photo Tighten the screws using enclosed 2 5 mm Allen Key STEP 1 STEP 2 PUMP HOLDER DDC PUMP M4 x 25 DIN7984 M4 x 20 DIN7984 ...

Page 10: ...rsion To enable installation of the reservoir where clearance for the pump is required EK supplies a pair of FLT mounts along with M4 nuts washers and additional screws In case of using standard fan mounting location only one supplied mount is required STEP 1 Position the mounts as shown on the picture ...

Page 11: ... 11 STEP 2 Screw the mounts in place using supplied M4 x 8 screws and 2 5 mm allen key STEP 2 M4 x 8 DIN7984 M4 x 8 DIN7984 D5 Version DDC Version ...

Page 12: ...984 Screws using M2 5 Allen Key Tighten the screws evenly STEP 1 INSTALLING EK QUANTUM KINETIC FLT USING UNI PUMP BRACKET ATTACHING EK QUANTUM KINETIC FLT WITH SUPPLIED MOUNTS 3a Included M4 nuts washers and M4 x 10 screws can be used to mount the flat reservoir to a fan M4 x 8 DIN7984 UNI PUMP BRACKET M4 x 10 DIN7984 M4 Washer M4 Nut ...

Page 13: ...ur radiator the reservoir can be mounted onto the radiator and 25 mm thick fans together UNC 6 32 x 30 ISO 7380 Screw 3c Alternatively the shorter 5mm long screws from the radiator may be used to mount only the reservoir UNC 6 32 x 5 ISO 7380 Screw ...

Page 14: ...orts should be blocked using G1 4 plugs Optional INLET DRAIN FILL OUTLET 3d Lastly the supplied M4 nuts washers and M4 x 10 screws may be used to secure the reservoir to a case with the mounts This is useful when there is no clearance behind for the pump or to prevent all airflow being blocked M4 x 10 DIN7984 M4 Washer M4 Nut ...

Page 15: ...ER RGB HEADER To ensure the installation of EK components was successful we recommend you perform a 24 hour leak test When your loop is complete and filled with coolant connect the pump to a PSU outside your system Do not connect power to any of the other components Turn on the PSU and let the pump run continuously It is normal for the coolant level to drop during this process as air collects in t...

Page 16: ...page with TECHNICAL SPECIFICATIONS AND PRODUCT PARTS where you can find the EAN number of each part you might need Include the EAN number with quantity in your request Mounting Mechanism EAN can be found under BOX CONTENTS Thermal pads are readily available in the EK shop EKWaterBlocks EKWaterBlocks ekwaterblocks ekwaterblocks EKWBofficial SUPPORT AND SERVICE SOCIAL MEDIA ...

Reviews: