2-2
Connections
Connection overview
WARNING
To prevent electric shock, test connections must be configured such that
the user cannot come in contact with conductors or any DUT that is in
contact with the conductors. Safe installation requires proper shields, bar-
riers, and grounding to prevent contact with conductors. Operator protec-
tion and safety are the responsibility of the person installing the product.
WARNING
During power-up, voltage spikes may appear on the terminals of the
SourceMeter. These voltage spikes could be at hazardous levels (>42.4V
peak) and could damage sensitive DUTs. Never touch external circuitry or
the test leads when powering up the SourceMeter. It is good practice to
always disconnect DUTs from the SourceMeter before powering up the
SourceMeter.
WARNING
Up to 210V may be present on the output and guard terminals. To prevent
electrical shock that could cause injury or death, NEVER make or break
connections to the SourceMeter while it is on or is connected to an external
source.
Connecting Remote PreAmp to the mainframe
WARNING
Potentially hazardous source voltage is routed from the mainframe to the
Remote PreAmp via the preamp cable. Adhere to the following safety pre-
cautions to prevent electric shock:
•
The SourceMeter must be turned off before connecting (or disconnect-
ing) the Remote PreAmp to the mainframe.
•
When not using the Remote PreAmp, disconnect the preamp cable at
the rear panel of the mainframe. DO NOT leave the preamp cable con-
nected to the mainframe if the other end is not connected to the Remote
PreAmp.
•
ALWAYS re-install the plastic safety cover onto the mainframe preamp
connector whenever the Remote PreAmp is not being used.
Use the supplied preamp cable to connect the Remote PreAmp to the mainframe as follows:
1.
From the front panel of the SourceMeter, turn the POWER off.
2.
Connect the preamp cable to the Remote PreAmp. The preamp connector on the
Remote PreAmp is labeled “MAINFRAME.”
Summary of Contents for 6430
Page 26: ......
Page 32: ......
Page 78: ...2 14 Connections ...
Page 98: ...3 20 Basic Source Measure Operation ...
Page 138: ...5 30 Source Measure Concepts ...
Page 156: ...6 18 Range Digits Speed and Filters ...
Page 168: ...7 12 Relative and Math ...
Page 176: ...8 8 Data Store ...
Page 202: ...9 26 Sweep Operation ...
Page 248: ...11 22 Limit Testing ...
Page 310: ...16 6 SCPI Signal Oriented Measurement Commands ...
Page 418: ...17 108 SCPI Command Reference ...
Page 450: ...18 32 Performance Verification ...
Page 477: ...A Specifications ...
Page 489: ...B StatusandErrorMessages ...
Page 498: ...B 10 Status and Error Messages ...
Page 499: ...C DataFlow ...
Page 503: ...D IEEE 488BusOverview ...
Page 518: ...D 16 IEEE 488 Bus Overview ...
Page 519: ...E IEEE 488andSCPI ConformanceInformation ...
Page 523: ...F MeasurementConsiderations ...
Page 539: ...G GPIB488 1Protocol ...
Page 557: ......