SCPI Command Reference
17-55
Query
[:ON]?
Query functions that are enabled
:OFF?
Query functions that are disabled
Description
When concurrent measurements are enabled, these commands are used to
enable or disable functions to be measured. The [:ON] command is used to
include (enable) one or more measurement functions in the list, and the
:OFF command is used to remove (disable) one or more functions from the
list.
Note that each function speci
fi
ed in the list must be enclosed in single or
double quotes, and functions must be separated by commas (,). Examples:
:FUNCtion
“
VOLTage
”
,
“
CURRent
”
Enable volts and amps functions
:FUNCtion:OFF
‘
VOLTage
’
,
‘
CURRent
’
Disable volts and amps functions
Note that there is a stand-alone command that can be used to enable or dis-
able all three measurement functions. See :ALL.
If concurrent measurements (:CONCurrent) are disabled, the :ON command
can only turn on one function at a time.
:ALL
[:SENSe[1]]:FUNCtion[:ON]:ALL
Enable all measurement functions
[:SENSe[1]]:FUNCtion:OFF:ALL
Disable all measurement functions
Description
This command is used to enable or disable all measurement functions.
When enabled (:ON:ALL), amps, volts, and ohms measurements will be
performed simultaneously if concurrent measurements are enabled. See
:CONCurrent. If concurrent measurements are disabled, only the ohms
function will be enabled.
The :OFF:ALL command disables all measurements.
:COUNt?
[:SENSe[1]]:FUNCtion[:ON]:COUNt?
Query number of functions enabled
[:SENSe[1]]:FUNCtion:OFF:COUNt?
Query number of functions disabled
Description
This query command is used to determine the number of functions that are
enabled or disabled.
When :ON:COUNt? is sent, the response message will indicate the number
of functions that are enabled.
When :OFF:COUNt? is sent, the response message will indicate the number
of functions that are disabled.
:STATe? <name>
[:SENSe[1]]:FUNCtion:STATe <name>
Query state of speci
fi
ed function
Parameters
<name> =
“
CURRent[:DC]
”
Amps measurement function
“
VOLTage[:DC]
”
Volts measurement function
“
RESistance
”
Ohms measurement function
Summary of Contents for 6430
Page 26: ......
Page 32: ......
Page 78: ...2 14 Connections ...
Page 98: ...3 20 Basic Source Measure Operation ...
Page 138: ...5 30 Source Measure Concepts ...
Page 156: ...6 18 Range Digits Speed and Filters ...
Page 168: ...7 12 Relative and Math ...
Page 176: ...8 8 Data Store ...
Page 202: ...9 26 Sweep Operation ...
Page 248: ...11 22 Limit Testing ...
Page 310: ...16 6 SCPI Signal Oriented Measurement Commands ...
Page 418: ...17 108 SCPI Command Reference ...
Page 450: ...18 32 Performance Verification ...
Page 477: ...A Specifications ...
Page 489: ...B StatusandErrorMessages ...
Page 498: ...B 10 Status and Error Messages ...
Page 499: ...C DataFlow ...
Page 503: ...D IEEE 488BusOverview ...
Page 518: ...D 16 IEEE 488 Bus Overview ...
Page 519: ...E IEEE 488andSCPI ConformanceInformation ...
Page 523: ...F MeasurementConsiderations ...
Page 539: ...G GPIB488 1Protocol ...
Page 557: ......