17-4
SCPI Command Reference
Command
Description
Default
parameter SCPI
Source
memory
:CALCulate2
:LIMit[1]
:COMPliance
:SOURce2 <NRf>
| <NDN>
:SOURce2?
:STATe <b>
:STATe?
:FAIL?
:LIMit2
:UPPer
[:DATA] <n>
[:DATA]?
:SOURce2 <NRf>
| <NDN>
:SOURce2?
:LOWer
[:DATA] <n>
[:DATA]?
:SOURce2 <NRf>
| <NDN>
:SOURce2?
:PASS
:SOURce2 <NRf>
| <NDN>
:SOURce2?
:STATe <b>
:STATe?
:FAIL?
:LIMit3
:UPPer
[:DATA] <n>
[:DATA]?
:SOURce2 <NRf>
| <NDN>
:SOURce2?
Specify output
“
fail
”
pattern (0 to 7, 3-bit;
0 to 15, 4-bit).
2
Query
“
fail
”
bit pattern.
1
Enable or disable Limit 1 test.
Query state of Limit 1 test.
Returns result of Limit 1 test: 0 (pass) or 1 (fail).
Path to control LIMIT 2 test:
Con
fi
gure upper limit:
Specify upper limit (-9.999999e20 to
9.999999e20).
Query upper limit.
Specify output
“
fail
”
pattern for grading mode
(0 to 7, 3-bit;0 to 15, 4-bit).
2
Query
“
fail
”
bit pattern.
1
Con
fi
gure lower limit:
Specify lower limit (-9.999999e20 to
9.999999e20).
Query lower limit.
Specify output
“
fail
”
pattern for grading mode
(0 to 7, 3-bit; 0 to 15, 4-bit).
2
Query
“
fail
”
bit pattern.
1
Path to specify
“
pass
”
pattern for sorting mode:
Specify output
“
pass
”
pattern (0 to 7, 3-bit;
0 to 15, 4-bit).
2
Query
“
pass
”
bit pattern.
1
Enable or disable Limit 2 test.
Query state of Limit 2 test.
Return result of Limit 2 test: 0 (pass) or 1 (fail).
Path to control LIMIT 3 test:
Con
fi
gure upper limit:
Specify upper limit (-9.999999e20 to
9.999999e20).
Query upper limit.
Specify output
“
fail
”
pattern (0 to 7, 3-bit;
0 to 15, 4-bit).
2
Query
“
fail
”
bit pattern.
1
15 or 7
OFF
1
15 or 7
-1
15 or 7
15 or 7
OFF
1
15 or 7
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
1
The format (ASCII, hexadecimal, octal, or binary) for the returned value is set by FORMat:SOURce2 <name>.
2
Default based on present digital output size (:SOURce2:BSIZe <n>). 3-bit default is 7. 4-bit default is 15. 16-bit default is 65535.
Table 17-1 (cont.)
CALCulate command summary
Summary of Contents for 6430
Page 26: ......
Page 32: ......
Page 78: ...2 14 Connections ...
Page 98: ...3 20 Basic Source Measure Operation ...
Page 138: ...5 30 Source Measure Concepts ...
Page 156: ...6 18 Range Digits Speed and Filters ...
Page 168: ...7 12 Relative and Math ...
Page 176: ...8 8 Data Store ...
Page 202: ...9 26 Sweep Operation ...
Page 248: ...11 22 Limit Testing ...
Page 310: ...16 6 SCPI Signal Oriented Measurement Commands ...
Page 418: ...17 108 SCPI Command Reference ...
Page 450: ...18 32 Performance Verification ...
Page 477: ...A Specifications ...
Page 489: ...B StatusandErrorMessages ...
Page 498: ...B 10 Status and Error Messages ...
Page 499: ...C DataFlow ...
Page 503: ...D IEEE 488BusOverview ...
Page 518: ...D 16 IEEE 488 Bus Overview ...
Page 519: ...E IEEE 488andSCPI ConformanceInformation ...
Page 523: ...F MeasurementConsiderations ...
Page 539: ...G GPIB488 1Protocol ...
Page 557: ......