SCPI Command Reference 17-105
With BUS selected, the event occurs when a GET or *TRG command is
sent over the bus.
With NSTESt selected, the event occurs when the SOT (start of test) low
pulse is received from a component handler via the Digital I/O port. This is
used for limit testing.
With PSTest selected, the event occurs when SOT (start of test) high pulse is
received from a component handler via the Digital I/O port. This is used for
limit testing.
:TIMer <n>
:ARM[:SEQuence[1]][:LAYer[1]]:TIMer <n>
Set interval for arm layer timer
Parameters
<n> =
0.001 to 9999.999
Specify timer interval in seconds
10000.00 to 99999.99 Specify timer interval in seconds
Query
:TIMer?
Query programmed timer interval
Description
These commands are used to set the interval for the timer. Note that the
timer is in effect only if the timer is the selected control source.
:DIRection <name>
:ARM[:SEQuence[1]][LAYer[1]][:TCON
fi
gure]:DIRection <name>Control arm bypass
:TRIGger[:SEQuence[1]][:TCON
fi
gure]:DIRection <name>
Control trigger bypass
Parameters
<name> =
SOURce
Enable control source bypass
ACCeptor
Disable control source bypass
Query
:DIRection?
Query state of bypass
Description
This command is used to enable (SOURce) or disable (ACCeptor) control
source bypass. When enabled, operation will loop around the control source
on the
fi
rst pass in the layer. After that, repeat passes in the layer are held up
and will wait for the programmed control source event.
INPut <event list>
:TRIGger[:SEQuence[1]][:TCON
fi
gure][:ASYNchronous]:INPut <event list>
Enable event detectors
Parameters
<event list> = SOURce
Enable Source Event Detector
DELay
Enable Delay Event Detector
SENSe
Enable Measure Event Detector
NONE
Disable all event detectors in Trigger Layer
NOTE
Each event in the list must be separated by a comma (i.e. trigger:input source, delay,
sense).
Query
:INPut?
Query enabled event detectors in Trigger Layer
Summary of Contents for 6430
Page 26: ......
Page 32: ......
Page 78: ...2 14 Connections ...
Page 98: ...3 20 Basic Source Measure Operation ...
Page 138: ...5 30 Source Measure Concepts ...
Page 156: ...6 18 Range Digits Speed and Filters ...
Page 168: ...7 12 Relative and Math ...
Page 176: ...8 8 Data Store ...
Page 202: ...9 26 Sweep Operation ...
Page 248: ...11 22 Limit Testing ...
Page 310: ...16 6 SCPI Signal Oriented Measurement Commands ...
Page 418: ...17 108 SCPI Command Reference ...
Page 450: ...18 32 Performance Verification ...
Page 477: ...A Specifications ...
Page 489: ...B StatusandErrorMessages ...
Page 498: ...B 10 Status and Error Messages ...
Page 499: ...C DataFlow ...
Page 503: ...D IEEE 488BusOverview ...
Page 518: ...D 16 IEEE 488 Bus Overview ...
Page 519: ...E IEEE 488andSCPI ConformanceInformation ...
Page 523: ...F MeasurementConsiderations ...
Page 539: ...G GPIB488 1Protocol ...
Page 557: ......