Page 1: ...OPERATION MANUAL FOR GAUGE UNIT ZX400 Sanmenxia ZhongyuanJingmiCo Ltd...

Page 2: ...e gage head contacts CAUTIONS Be sure not to operate this system when the gagging unit and or control unit are in failure such as when the READY signal has gone off Heavy load or strong force can defo...

Page 3: ...s such as alcohol to clean the device ABOUT CARRYING ABROAD Due to the various local rules please inform us before taking this device out of China Our company will not be responsible for any overseas...

Page 4: ...Features 2 3 Extension Function 3 4 Interface 4 4 1 Measuring Interface 5 4 2 Setting Interface 6 4 3 Adjustment Interface 7 5 I O Interface And Connection 8 6 WSD 100 external receiving power signal...

Page 5: ...cessed or after the size of the workpiece with electric sensor for measurement if the use of air momentum meter for measurement it needs to be measured through the pneumatic probe and AE converter The...

Page 6: ...ocess display a variety of measurement results and judge the status of the point while sending a signal to control the movement of the machine 2 Convenient and compact Using 3 5 inch TFT touch screen...

Page 7: ...hole machine can meet the industrial interference test 3 Extension Functions 1 External compensation The measured data are compensated and zeroed according to external input signals 2 Memory selection...

Page 8: ...e function Windows measuring setting and adjusting The system defaults into the measurement module Click the button to enter the setting window Click the button to enter the adjustment window Click th...

Page 9: ...rement interface Window functions The measured value of the measuring item is displayed adjusted and displayed in digital form Instruction Displays the measured value of the measured item Display sign...

Page 10: ...ange the setting parameters click the number section and the keyboard pops up for setting Instruction P1 Signal points of rough grinding P2 Signal points of fine grinding P3 Light grinding signal poin...

Page 11: ...after processing Reset value the compensation value of the probe by the system after resetting Multiplier the probe amplification ratio can be set through the pop up keyboard The factory has been set...

Page 12: ...mber I 0 Single item Thread color Remarks 1 OUT 1 P1 Orange 2 OUT 2 P2 Yellow 3 OUT 3 P3 Pink 4 OUT 4 P4 Blue 5 OUT 5 Receipt OK Brown 6 OUT 6 Green 7 OUT 7 Light green 8 IN 1 Red White 9 COM OUT COMO...

Page 13: ...ng power signal meter WSD 100 External receiving power signal meter Terminal number ZHD 1140BC ZHS 173DC 1 AC 220V 2 AC 0V 3 Red line 4 Yellow line 5 Black line COM 6 Retract input switch signal 7 Ret...

Page 14: ...ndow the interface displays G1 records the size of the display value adjusts the lower contact makes the display value change to about half of the initial value locks the lower contact and then contin...

Page 15: ...e boot screen and press the button below the screen or set the display value after compensation to 0 Adjust the contact away from the measuring surface Click the system enters the adjustment window th...

Page 16: ...of the measuring device or measuring rod Adjust the upper and lower contact away from the measuring surface Click the system enters the adjustment window and the interface displays G1 Adjust the lowe...

Page 17: ...V1 4 20211108 Sanmenxia ZhongyuanJingmiCo Ltd Address east section of weiliu road sanmenxia industrial park henan China Tel 0398 2751818 Fax 0398 2751819 Postcode 472000 http www zyjm com...