background image

 

®

 

  

Badger Meter Europa GmbH

 

 
 
 
 

Field Verification Device 

 

for ModMAG

®

 M1000, M2000 and  

B-MAG

 

I M5000 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
USER MANUAL 

 
 
 
July 2016 
 
 
 
 
 
MID_VD_BA_02_1607

Summary of Contents for ModMAG M1000

Page 1: ...Badger Meter Europa GmbH Field Verification Device for ModMAG M1000 M2000 and B MAG I M5000 USER MANUAL July 2016 MID_VD_BA_02_1607...

Page 2: ...pad 11 5 Menu structure 12 6 Settings 13 7 Tests 15 7 1 Main test 15 7 2 Manual tests 16 7 2 Amplifier test 16 7 3 Detector test 16 7 5 Main test fails 17 7 6 Meter identification 17 7 7 About 17 8 PC...

Page 3: ...46 and needs to be protected against dripping water water oils etc Setup operation Adjust only those controls that are covered by the operating instructions Improper adjustment of other controls may...

Page 4: ...____________ Tag number if applicable 2 3 Product description Field Verification Device is a portable test device for the electromagnetic flow meters type ModMAG M1000 M2000 and B MAG I M5000 With the...

Page 5: ...ined durable plastic case and includes the following components 1 3 pcs verification cable harnesses For the ModMAG M1000 ModMAG M2000 and one for the B MAG I M5000 meters 2 4 pcs AC power conversion...

Page 6: ...ther ModMAG M1000 M2000 or B MAG I M5000 on the outer harness wire cover so that the user can differentiate between the two Connect the 25 pin connector of the corresponding cable harness to the top o...

Page 7: ...s from front of the amplifier 2 Loosen the two lower screws until the screw heads protrude above the surface of the amplifier door 3 Open the amplifier lift up the door Connecting the cable harness Th...

Page 8: ...tor labeled CS C2 C1 4 Plug the Output 1 2 Input into the board output connector labeled 1 to 6 5 Plug the Analog Output into the board output connector labeled 9 to 8 6 Plug the RS232 connector into...

Page 9: ...ier A connection instruction label has been placed inside of the amplifier for connection reference On ModMAG M2000 cable harness are following connectors 9 Output 1 2 RS232 7 pins 10 Output 3 4 Input...

Page 10: ...led Detector Coil to the 3 wire connector from the detector BA2000 22MID L N PE JP1 JP2 COMMUNICATION DISPLAY CS C2 C1 E1 ES E2 RS EP ES 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Output 1 2 RS232 Output...

Page 11: ...onnected onto the internal circuit board of the amplifier A connection instruction label has been placed inside the amplifier for connection reference On B MAG I M5000 cable harness are following conn...

Page 12: ...he harness wire connector labeled Detector Electrode to the 5 wire connector from the detector 10 Connect the harness wire connector labeled Detector Coil to the 2 wire connector from the detector OUT...

Page 13: ...eys on the left and right sides of the up arrow key provide menu access wet or dry detector selection The up down left and right keys allow menu navigation The OK key confirms a menu selection The lef...

Page 14: ...Test ID Detector Dry Wet Flow Meter Flow Meter Ident Amplifier Detector Current Analog Input Analog Output Inputs Outputs Empty Pipe Detector Coil Resistance Electrode Impedance Isolation Main Test f...

Page 15: ...Select a menu item from the StartMenu Menu User Settings MISC Language with the upper right function key 2 Select the appropriate language the default language is English Date 1 Select a menu item fro...

Page 16: ...t a menu item from the StartMenu Settings FM Modbus address 2 Edit the address in the editbox by using the numeric keypad Use the Delete arrow key to remove the last number position 3 Press the upper...

Page 17: ...tarts 4 Press the On Off button on the Verification Device and wait for the SelfTest to complete 5 When the Start Menu appears on the display press the upper left function key 6 When the Main Test opt...

Page 18: ...on the Verification Device and wait for the SelfTest to complete 5 When the Start Menu appears on the display press the upper left function key 6 Select the menu Flow Meter and press the OK button 7...

Page 19: ...oduct name Serial number Firmware name and version Compilation date Otp Boot Checksum Flash Os Checksum 7 7 About Information about your Verification Device Serial number Version Compilation date Flas...

Page 20: ...Page 18 23 MID_VD_BA_02_1607 8 PC software 8 1 Installation of the PC software Insert the delivered CD open setup exe and follow the instructions An icon on the desktop will be installed named Verific...

Page 21: ...the device and press OK If the window does not open click FILE and OPEN Ctrl O in the upper task line 4 The measurements are automatically downloaded to the PC You will be asked if the measurements w...

Page 22: ...t which you want to print out 2 Click FILE and PRINT 3 A preview window appears 4 Optional You can change the format of the protocol to print more details for service people 5 Click printer symbol for...

Page 23: ...ort reports 1 Select Export all for all or Export selected for exporting one measurement 2 Save the data in CSV format to be imported in MS Excel 8 5 Language selection 1 Select TOOLS and OPTIONS 2 Th...

Page 24: ...no high voltage noise disturbing the coil circuit provides certified printout showing test results is capable to store 100 meter tests 9 2 Accessories Test cable for ModMAG M2000 connection Test cable...

Page 25: ...ir Harmlessness declaration Page 23 23 MID_VD_BA_02_1607 10 Return of goods for repair Harmlessness declaration Please refer to our claims return form harmlessness declaration under www badgermeter de...

Page 26: ...line Phone 49 7025 9208 0 or 30 Fax 49 7025 9208 15 Badger Meter Europa GmbH Subsidiary of Badger Meter Inc USA N rtinger Strasse 76 72639 Neuffen Germany E mail badger badgermeter de www badgermeter...

Reviews: