Secondary
Microprocessor
VRM Connectors
Primary
Microprocessor
VRM Connectors
Microprocessor
Core-Frequency-Selection
Switch Block (SW1)
Primary
Microprocessor
Connector
Secondary
Microprocessor
Connector
DIMM Socket 4
DIMM Socket 3
DIMM Socket 2
DIMM Socket 1
2. Install the microprocessor in the primary
microprocessor connector.
a. Touch the static-protective package containing
the new microprocessor to any unpainted metal
surface on the server; then remove the
microprocessor from the package.
b. Hold the microprocessor
.1ð/
by the open
latches
.3/
and center the microprocessor over
the microprocessor connector.
c. Make sure the microprocessor is oriented and
aligned correctly.
d. Insert the microprocessor into the guides until it
seats in the connector. Close the latches.
3. Install the two VRMs (voltage regulator modules)
.9/
in the primary microprocessor VRM connectors.
a. Center one VRM over the connector.
b. Make sure the VRM is oriented and aligned
correctly.
c. Press the VRM into the connector until the VRM
latches snap into the locked position.
d. Repeat this procedure to install the other VRM.
4. If you are installing a second microprocessor kit,
complete this procedure.
a. Remove the terminator card
.5/
from the
secondary microprocessor connector
.6/
.
b. Refer to the procedure in step 2 and install the
secondary microprocessor
.4/
.
c. Refer to the procedure in step 3 and install the
two VRMs
.7/
in the secondary microprocessor
VRM connectors
.8/
.
5. Set the microprocessor core-ratio-selection switch
(SW1) for the correct microprocessor core ratio. For
example, if you have a 450 MHz microprocessor
installed, be sure that the microprocessor
core-ratio-selection switch is set to a microprocessor
352
Netfinity Server HMM
Summary of Contents for 866011U - Netfinity 5500 - 8660
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Page 244: ...Screws 236 Netfinity Server HMM...
Page 247: ...Netfinity 5500 Type 8660 239...
Page 314: ...306 Netfinity Server HMM...
Page 324: ...316 Netfinity Server HMM...
Page 325: ...Related service information 317...
Page 326: ...318 Netfinity Server HMM...
Page 327: ...Related service information 319...
Page 340: ...332 Netfinity Server HMM...
Page 341: ...Related service information 333...
Page 346: ...338 Netfinity Server HMM...
Page 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...