A screen similar to the following appears.
Add Physical Drive(s) to Array
Options:
Logical
Drive
Raid
Level
Size
(MB)
New Size
(MB)
Increase the capacity of all logical drives in array B
0
1
2
5
0
5
1000
498
300
1500
664
450
OK
Cancel
5. Select one of the available options for expansion from
the pull-down list.
The screen shows a list of the affected logical drives
with their new sizes.
6. Click on OK.
Physical device administration:
This section
contains instructions for setting physical device states and
rebuilding drives using the ServeRAID Administration and
Monitoring utility program.
Setting Physical device states:
Physical devices
always appear in one of the following defined states, but
you can easily redefine them into another state.
The following table shows the valid device states and valid
alternative states.
Device States
Alternate States
EMP
RDY SBY
SBY
RDY EMP HSP SHS
DHS
EMP HSP SHS
SHS
HSP DHS
DDD
ONL RBL
RDY
EMP HSP SHS SBY
HSP
RDY SHS DHS
ONL
DDD
RBL
DDD ONL
To change the physical device state:
1. Select the device from the Main Screen of the
Administration and Monitoring utility program. A
screen similar to the following appears.
42
Netfinity Server HMM
Summary of Contents for 866011U - Netfinity 5500 - 8660
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Page 244: ...Screws 236 Netfinity Server HMM...
Page 247: ...Netfinity 5500 Type 8660 239...
Page 314: ...306 Netfinity Server HMM...
Page 324: ...316 Netfinity Server HMM...
Page 325: ...Related service information 317...
Page 326: ...318 Netfinity Server HMM...
Page 327: ...Related service information 319...
Page 340: ...332 Netfinity Server HMM...
Page 341: ...Related service information 333...
Page 346: ...338 Netfinity Server HMM...
Page 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...