Error Code/Symptom
FRU/Action
035-XXX-300
DUPLICATE ERROR CODE
(Failed RAID test on PCI
slot 3. Check System Error
Log before replacing a
FRU.)
1. Adapter
2. SCSI Backplane
3. Cable
035-XXX-300
DUPLICATE ERROR CODE
(Check System Error Log
before replacing a FRU.)
1. Fixed Disk with SCSI
ID 00 on RAID
adapter in PCI slot 3
035-XXX-3NN
(Check System Error Log
before replacing a FRU.
NN = SCSI ID of failing
fixed disk.)
1. Fixed Disk with SCSI
ID NN on RAID
adapter in PCI slot 3
035-XXX-400
DUPLICATE ERROR CODE
(Failed RAID test on PCI
slot 4. Check System Error
Log before replacing a
FRU.)
1. Adapter
2. SCSI Backplane
3. Cable
035-XXX-400
DUPLICATE ERROR CODE
(Check System Error Log
before replacing a FRU.)
1. Fixed Disk with SCSI
ID 00 on RAID
adapter in PCI slot 4
035-XXX-4NN
(Check System Error Log
before replacing a FRU.
NN = SCSI ID of failing
fixed disk.)
1. Fixed Disk with SCSI
ID NN on RAID
adapter in PCI slot 4
035-XXX-500
DUPLICATE ERROR CODE
(Failed RAID test on PCI
slot 5. Check System Error
Log before replacing a
FRU.)
1. Adapter
2. SCSI Backplane
3. Cable
035-XXX-500
DUPLICATE ERROR CODE
(Check System Error Log
before replacing a FRU.)
1. Fixed Disk with SCSI
ID 00 on RAID
adapter in PCI slot 5
035-XXX-5NN
(Check System Error Log
before replacing a FRU.
NN = SCSI ID of failing
fixed disk.)
1. Fixed Disk with SCSI
ID NN on RAID
adapter in PCI slot 5
035-253-N00
(RAID initialization error for
adapter in PCI slot number
N.)
1. ServeRAID Adapter is
not configured
correctly. Refer to the
ServeRAID Hardware
Maintenance Manual
for more information.
075-XXX-000
(Failed Power Supply test)
1. Power Supply
272
Netfinity Server HMM
Summary of Contents for 866011U - Netfinity 5500 - 8660
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Page 244: ...Screws 236 Netfinity Server HMM...
Page 247: ...Netfinity 5500 Type 8660 239...
Page 314: ...306 Netfinity Server HMM...
Page 324: ...316 Netfinity Server HMM...
Page 325: ...Related service information 317...
Page 326: ...318 Netfinity Server HMM...
Page 327: ...Related service information 319...
Page 340: ...332 Netfinity Server HMM...
Page 341: ...Related service information 333...
Page 346: ...338 Netfinity Server HMM...
Page 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...