9. Pull the shuttle
.7/
toward the back of the server.
10. Connect one of the connectors on the SCSI cable for
the removable-media drive bays
.6/
to the back of
the drive
.5/
.
11. Connect a power cable to the back of the drive.
Power cables for removable-media drives come
installed in the server. The connectors are keyed and
can be inserted only one way.
12. If you are installing another 5.25-inch drive, do so at
this time. Otherwise, continue with the next step.
13. Push the shuttle
.7/
toward the front of the server
and tighten the four thumbscrews
.8/
at the back of
the shuttle.
14. Install the media-bay trim bezel and the NetBAY3
bezel that you removed earlier. (See “Installing the
trim bezels and server door” on page 156)
15. If you have other options to install or remove, do so
now; otherwise, go to “Completing the installation” on
page 154.
Installing a drive in a hot-swap bay:
The
bays on the right front of the server support hot-swap
drives only.
Note
You do not have to turn off the server to install
hot-swap drives in these bays. However, you must
turn off the server when performing any steps that
involve installing or removing cables.
Before you begin:
Read “Safety information” on page 308.
Read the documentation that comes with the
drive.
Reviewed “ServeRAID Configuration program” on
page 74. for information about the RAID
controller and disk-array configuration.
Prepare the drive for installation (see
“Preinstallation steps (all bays)” on page 200).
Refer to the following illustration while you perform the
steps in this procedure.
Netfinity 5500 - Type 8660
203
Summary of Contents for 866011U - Netfinity 5500 - 8660
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Page 244: ...Screws 236 Netfinity Server HMM...
Page 247: ...Netfinity 5500 Type 8660 239...
Page 314: ...306 Netfinity Server HMM...
Page 324: ...316 Netfinity Server HMM...
Page 325: ...Related service information 317...
Page 326: ...318 Netfinity Server HMM...
Page 327: ...Related service information 319...
Page 340: ...332 Netfinity Server HMM...
Page 341: ...Related service information 333...
Page 346: ...338 Netfinity Server HMM...
Page 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...