Error Code/Symptom
FRU/Action
176
(Computer cover or cable
cover was removed without
a key being used)
1. Run
Configuration/Setup
2. System Board
177, 178
(Security hardware error)
1. Run
Configuration/Setup
2. Service Processor
Adapter
3. System Board
184
(Power-on password
corrupted)
1. Run
Configuration/Setup
2. System Board
185
(Drive startup sequence
information corrupted)
1. Run
Configuration/Setup
2. System Board
186
1. Run
Configuration/Setup
2. System Board
187
(VPD serial number not set.)
1. Set serial number in
Setup
2. System Board
188
(Bad EEPROM CRC #2)
1. Run
Configuration/Setup
2. System Board
189
(An attempt was made to
access the server with
invalid passwords)
1. Run
Configuration/Setup,
enter the
administrator
password
195
(Processor 1 is not
functioning)
1. VRM 1
2. Processor 1
3. Processor Board
4. System Board
196
(Processor 2 is not
functioning)
1. VRM 2
2. Processor 2
3. Processor Board
4. System Board
197
(Processor 1 failed BIST)
1. Processor 1
2. Processor Board
3. System Board
198
(Processor 2 failed BIST)
1. Processor 2
2. Processor Board
3. System Board
201
(Memory test error, see
“Memory settings” on
page 98)
1. DIMM
2. Processor Board
3. System Board
229
(Cache error)
1. Processor
2. Optional Processor
(if installed)
3. Processor Board
Netfinity 5500 - Type 8660
281
Summary of Contents for 866011U - Netfinity 5500 - 8660
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Page 244: ...Screws 236 Netfinity Server HMM...
Page 247: ...Netfinity 5500 Type 8660 239...
Page 314: ...306 Netfinity Server HMM...
Page 324: ...316 Netfinity Server HMM...
Page 325: ...Related service information 317...
Page 326: ...318 Netfinity Server HMM...
Page 327: ...Related service information 319...
Page 340: ...332 Netfinity Server HMM...
Page 341: ...Related service information 333...
Page 346: ...338 Netfinity Server HMM...
Page 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...