Synchronization completed
–
Migration started
–
Migration completed
Warning messages
–
PFA event detected
Critical messages
–
Dead drive detected
–
ServeRAID controller not responding to
commands
By knowing what these types of messages are, the system
administrator can then configure Netfinity Manager with
instructions for monitoring the server configuration and
specifying the appropriate action to take if an alert is
issued. For example, the system administrator can
program Netfinity Manager to dial out through a modem to
a specified phone number if a defunct drive is detected on
any server across the network.
Using the ServeRAID administration
functions:
This section describes how to administer
the ServeRAID controller using the following functions:
“Array administration”
“Logical drive administration” on page 34
“Logical drive migration administration” on page 38
“Physical device administration” on page 42
“ServeRAID controller administration” on page 45
Array administration:
This section contains
instructions for creating a disk array and deleting a disk
array using the ServeRAID Administration and Monitoring
utility program.
Creating Disk Arrays
To create a disk array:
1. Click on the
icon on the tool bar or select
Manage Disk Arrays from the Advanced pull-down
menu; then, select Create Disk Array.
Disk arrays provide access to hard disk drives
in a logical manner. Hard disk drives are
grouped in a disk array, and divided into
logical drives for access by the operating
system.
Netfinity 5500 - Type 8660
31
Summary of Contents for 866011U - Netfinity 5500 - 8660
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Page 244: ...Screws 236 Netfinity Server HMM...
Page 247: ...Netfinity 5500 Type 8660 239...
Page 314: ...306 Netfinity Server HMM...
Page 324: ...316 Netfinity Server HMM...
Page 325: ...Related service information 317...
Page 326: ...318 Netfinity Server HMM...
Page 327: ...Related service information 319...
Page 340: ...332 Netfinity Server HMM...
Page 341: ...Related service information 333...
Page 346: ...338 Netfinity Server HMM...
Page 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...