Create Logical Drive
Array
ID
Free
Space MB)
Raid
Level
Requested
Space
OK
Cancel
881
1762
1762
1906
A
A
B
0
2. Select the disk array ID for which you want to create
a logical drive.
3. Select the RAID level that you want to assign to the
logical drive from the pull-down list.
The RAID levels available depend on the number of
hard disk drives that you select for the disk array.
Notes:
a. If you have one hard disk drive, the logical drive
can be only RAID level 0.
b. If you have two or more hard disk drives, the
logical drive can be RAID level 0 or 1.
c. If you have three or more hard disk drives, the
logical drive can be RAID level 0, 1, or 5.
d. If you plan to use the Change RAID Level
feature of logical drive migration, you must
assign the same RAID level to all of the logical
drives in the array. See “Changing RAID levels”
on page 39 for more information.
4. Type the size, in megabytes, that you want to assign
to the logical drive in the Requested Space entry
field.
Notes:
a. The Requested Space default value is calculated
as the maximum logical drive size available for
the RAID level assigned.
b. The Requested Space must be between 2 MB
and the maximum available.
c. The actual logical drive size that appears might
be slightly different from what you type in the
Requested Space field.
The size of a logical drive is determined by the
RAID level and the number of hard disk drives.
For example, a disk array consisting of three,
1 GB hard disk drives with a requested RAID
level 0 drive of 1000 MB will actually contain only
999 MB because the data is striped across all
three drives, with 333 MB on each drive.
5. Click on OK to create the logical drive.
6. You
must initialize all new logical drives before storing
data in them. Continue with “Initializing logical drives”
on page 36.
Netfinity 5500 - Type 8660
35
Summary of Contents for 866011U - Netfinity 5500 - 8660
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Page 244: ...Screws 236 Netfinity Server HMM...
Page 247: ...Netfinity 5500 Type 8660 239...
Page 314: ...306 Netfinity Server HMM...
Page 324: ...316 Netfinity Server HMM...
Page 325: ...Related service information 317...
Page 326: ...318 Netfinity Server HMM...
Page 327: ...Related service information 319...
Page 340: ...332 Netfinity Server HMM...
Page 341: ...Related service information 333...
Page 346: ...338 Netfinity Server HMM...
Page 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...