Hot-swap power supply removal
The server comes with one power supply. You can add a
second power supply to provide redundant power. Each
power supply has two status indicators; see “Power
supplies” on page 224 for information about the status
indicators.
Attention
You cannot hot-swap a power supply if the server has
only one power supply installed.
Refer to the illustration in “Hot-swap power supply
installation” on page 181 while you perform the steps in
this procedure.
To remove a hot-swap power supply:
Caution
Never remove the cover on a power supply or any
part (power backplane and ac box) that has the
following label attached.
Hazardous voltage, current, and energy levels are
present inside the power supplies, power backplane,
and ac box. There are no serviceable parts inside the
power supplies, power backplane, or ac box.
1. If the server has only one power supply installed, turn
off the server and peripheral devices (see “Preparing
to install options” on page 220); otherwise, go to the
next step.
Attention
Before removing a functional power supply, set
the Power switch on the power supply to the Off
position.
2. Set the Power switch on the power supply that you
are removing to the Off position.
3. Remove the power supply
.4/
:
a. Remove the shipping screws
.9/
from the power
supply, if they have not already been removed.
Note
You do not need to replace the shipping
screws.
b. Remove the power-cord strain-relief bracket
.1ð/
, if one is installed.
Netfinity 5500 - Type 8660
185
Summary of Contents for 866011U - Netfinity 5500 - 8660
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Page 244: ...Screws 236 Netfinity Server HMM...
Page 247: ...Netfinity 5500 Type 8660 239...
Page 314: ...306 Netfinity Server HMM...
Page 324: ...316 Netfinity Server HMM...
Page 325: ...Related service information 317...
Page 326: ...318 Netfinity Server HMM...
Page 327: ...Related service information 319...
Page 340: ...332 Netfinity Server HMM...
Page 341: ...Related service information 333...
Page 346: ...338 Netfinity Server HMM...
Page 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...