Error Code/Symptom
FRU/Action
201-XXX-002
(Failed Memory test,
see“Memory settings” on
page 98 )
1. DIMM Location J2
201-XXX-003
(Failed Memory test,
see“Memory settings” on
page 98 )
1. DIMM Location J3
201-XXX-004
(Failed Memory test,
see“Memory settings” on
page 98 )
1. DIMM Location J4
201-XXX-999
(Multiple DIMM failure, see
error text.)
1. See error text for
failing DIMMs
202-XXX-001
(Failed System Cache test)
1. Microprocessor
202-XXX-002
(Failed System Cache test
on Optional Microprocessor)
1. Optional
Microprocessor
206-XXX-000
(Failed Diskette Drive test)
1. Diskette Drive cable
2. Diskette Drive
3. System Board
215-XXX-000
(Failed IDE CD-ROM test)
1. CD-ROM Drive
Cables
2. CD-ROM Drive
3. System Board
215-XXX-001
(Failed IDE test)
1. System Board
217-XXX-000
(Failed BIOS Fixed Disk
test)
Note
If RAID is configured,
the fixed disk number
refers to the RAID
logical array.
1. Fixed Disk 1
217-XXX-001
(Failed BIOS Fixed Disk
test)
Note
If RAID is configured,
the fixed disk number
refers to the RAID
logical array.
1. Fixed Disk 2
274
Netfinity Server HMM
Summary of Contents for 866011U - Netfinity 5500 - 8660
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Page 244: ...Screws 236 Netfinity Server HMM...
Page 247: ...Netfinity 5500 Type 8660 239...
Page 314: ...306 Netfinity Server HMM...
Page 324: ...316 Netfinity Server HMM...
Page 325: ...Related service information 317...
Page 326: ...318 Netfinity Server HMM...
Page 327: ...Related service information 319...
Page 340: ...332 Netfinity Server HMM...
Page 341: ...Related service information 333...
Page 346: ...338 Netfinity Server HMM...
Page 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...