8. Remove the
HardwareGuide CD and press
Ctrl
+
Alt
+
Del to restart the server.
Initializing, viewing, or synchronizing the
ServeRAID II controller configuration:
The
ServeRAID configuration information stored in nonvolatile
random-access memory (NVRAM) is critical to the reliable
operation of the disk array. To protect the integrity of the
configuration information, the configuration information is
also stored in an EEPROM and on each RBL and ONL
hard disk drive. Each time you change the configuration
information, all corresponding copies are updated
automatically.
During POST, if the NVRAM configuration information does
not match the configuration information stored in the
EEPROM or on the hard disk drives, an error message
appears.
You can use the Init/View/Synchronize Config menu to
initialize, view, or synchronize the ServeRAID controller
configuration information.
To initialize, view, or synchronize the configuration
information:
1. Start the ServeRAID Configuration program (see
“Starting the ServeRAID Configuration program” on
page 77).
2. Select Advanced Functions from the Main Menu;
then, press Enter.
3. Select Init/View/Synchronize Config from the next
menu; then, press Enter.
A screen similar to the following appears.
Bay
Array
Bay
Array
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Ch
1
Ch
2
INI
RDY
CDR
B
B
HSP
ONL
ONL
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
INI
Select a choice using the Up Arrow ( ) and Down Arrow ( ) keys and press Enter.
Press Esc to return to previous menu.
Main Menu
IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX
Adapter Number: 1
Bus Number: 0 Host ID = Null Config
A
A
ONL
ONL
A
ONL
Main Menu
1. Help
2. Initialize Configuration
3. View NVRAM Configuration
4. View EEPROM Configuration
5. View Hard Drive Configuration
6. View Change List
7. Configuration Synchronization
8. Exit
Init/View/Synchronize Config
Descriptions of the choices available from this menu
are as follows:
Help provides information about the choices
available on the menu. You also can press F1
from any screen to obtain online Help.
Initialize Configuration lets you set the
configuration of the ServeRAID controller to its
Netfinity 5500 - Type 8660
133
Summary of Contents for 866011U - Netfinity 5500 - 8660
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Page 244: ...Screws 236 Netfinity Server HMM...
Page 247: ...Netfinity 5500 Type 8660 239...
Page 314: ...306 Netfinity Server HMM...
Page 324: ...316 Netfinity Server HMM...
Page 325: ...Related service information 317...
Page 326: ...318 Netfinity Server HMM...
Page 327: ...Related service information 319...
Page 340: ...332 Netfinity Server HMM...
Page 341: ...Related service information 333...
Page 346: ...338 Netfinity Server HMM...
Page 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...