2. Select Rebuild/Device Management from the Main
Menu; then, press Enter.
3. Select Set Device State from the next menu; then,
press Enter.
4. Use the Up Arrow (
↑
) or Down Arrow (
↓
) key to
highlight the appropriate drive; then, press Enter.
A screen similar to the following appears.
Bay
Array
Bay
Array
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Ch
1
Ch
2
INI
RDY
CDR
B
B
HSP
ONL
ONL
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
INI
Select the state to change the drive to and press Enter.
Please wait.
IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX
Adapter Number: 1
Bus Number: 0 Host ID = Null Config
A
A
ONL
ONL
A
ONL
1. Help
2. Set Device State
3. Rebuild Drive
4. Display Drive Information
5. Erase Device Event Log
6. Exit
1. EMP
2. SBY
3. DHS
4. SHS
5. DDD
6. RDY
7. HSP
8, ONL
9. RBL
Rebuild/Device Management
Device States
The Drive States pop-up window lists all hard disk
drive states. (See “Physical device states” on
page 86 for more information.) The following table
shows the current device states and the valid
alternate device states that you can assign. For
example, you can change the state of a standby
hot-spare drive from SHS to HSP or DHS.
Note
Setting a DDD drive that is part of a CRT logical
drive to ONL without performing the rebuild
process might result in loss of data. (See
“Understanding the drive rebuild process” on
page 131 for more information.)
Device States
Alternate States
EMP
RDY SBY
SBY
RDY EMP HSP SHS
DHS
EMP HSP SHS
SHS
HSP DHS
DDD
ONL RBL
RDY
EMP HSP SHS SBY
HSP
RDY SHS DHS
ONL
DDD
RBL
DDD ONL
5. Use the Up Arrow (
↑
) or Down Arrow (
↓
) key to
highlight a valid alternate drive state; then, press
Enter. The new state appears in the Array/Bay
selection list.
6. If you want to change the state of another drive,
return to step 4. Otherwise, continue with step 7.
7. Press Esc to return to the Main Menu.
Netfinity 5500 - Type 8660
117
Summary of Contents for 866011U - Netfinity 5500 - 8660
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Page 244: ...Screws 236 Netfinity Server HMM...
Page 247: ...Netfinity 5500 Type 8660 239...
Page 314: ...306 Netfinity Server HMM...
Page 324: ...316 Netfinity Server HMM...
Page 325: ...Related service information 317...
Page 326: ...318 Netfinity Server HMM...
Page 327: ...Related service information 319...
Page 340: ...332 Netfinity Server HMM...
Page 341: ...Related service information 333...
Page 346: ...338 Netfinity Server HMM...
Page 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...