drive. Before you replace the drive, ensure
that:
1. All cables are connected correctly to the
backplane and to the hard disk drive.
Also, check to ensure that all cables
inside the server are connected correctly.
2. The hot-swap drive tray is seated
properly in the drive bay.
3. See “Symptom-to-FRU index” on
page 264.
DHS
A drive enters the Defunct Hot-spare (DHS)
state if:
1. A defunct (DDD) drive has been rebuilt to
another drive, such as a hot-spare drive.
2. A hot-spare (HSP) or standby hot-spare
(SHS) drive fails to respond to
commands from the ServeRAID
controller.
EMP
No device is present in the bay. This state
appears as dashes (– – –) on the ServeRAID
configuration screen, or as a blank space on
the Administration and Monitor utility screen.
HSP
A hot-spare (HSP) drive is a hard disk drive
that is defined for automatic use when a
similar drive fails. (See “Defining hot-spare
drives” on page 111 for more information.)
INI
The INI represents the initiator for the
ServeRAID controller.
ONL
The drive is online (ONL). It is functioning
properly and is part of an array.
PRC
The device is a generic SCSI controller (for
example, a hot-swap backplane that has
onboard systems-management support).
RBL
The drive is being rebuilt. (See
“Understanding the drive rebuild process” on
page 131 for more information.)
RDY
The ServeRAID controller recognizes a ready
(RDY) drive as being available for definition.
The ready drive state changes to empty
(EMP) when the drive is physically removed
from the bay.
SBY
A standby (SBY) drive is a hard disk drive that
the ServeRAID controller has spun down.
SHS
A standby hot-spare (SHS) is a hot-spare
drive that the ServeRAID controller has spun
down. If an online (ONL) drive becomes
defunct and no suitable hot-spare drive is
available, a standby hot-spare of the
appropriate size automatically spins up, and
enters the rebuild (RBL) state.
Netfinity 5500 - Type 8660
87
Summary of Contents for 866011U - Netfinity 5500 - 8660
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Page 244: ...Screws 236 Netfinity Server HMM...
Page 247: ...Netfinity 5500 Type 8660 239...
Page 314: ...306 Netfinity Server HMM...
Page 324: ...316 Netfinity Server HMM...
Page 325: ...Related service information 317...
Page 326: ...318 Netfinity Server HMM...
Page 327: ...Related service information 319...
Page 340: ...332 Netfinity Server HMM...
Page 341: ...Related service information 333...
Page 346: ...338 Netfinity Server HMM...
Page 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...