1. Click on the
icon on the tool bar or select
Manage Disk Arrays from the Advanced pull-down
menu; then, select Delete Disk Array.
A screen similar to the following appears.
Delete Disk Array
Array ID
OK
Cancel
B
A
B
2. Select the disk array ID that you want to delete from
the pull-down list.
3. Click on OK to delete the disk array.
Logical drive administration:
This section contains
instructions for creating a logical drive, initializing and
synchronizing a logical drive, and accessing blocked
logical drives using the ServeRAID Administration and
Monitoring utility program.
Creating Logical Drives
If you plan to use the logical-drive migration (LDM) feature,
do not create more than seven logical drives. The LDM
procedure requires one free logical drive to perform the
migration. See “Logical drive migration administration” on
page 38 for more information.
To create a logical drive:
.
1. Click on the
icon on the tool bar or
select Manage Logical Drive from the Advanced
pull-down menu; then, select Create Logical Drive.
A screen similar to the following appears.
You
must create at least one logical drive for
each disk array. You can create up to eight
logical drives.
34
Netfinity Server HMM
Summary of Contents for 866011U - Netfinity 5500 - 8660
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Page 244: ...Screws 236 Netfinity Server HMM...
Page 247: ...Netfinity 5500 Type 8660 239...
Page 314: ...306 Netfinity Server HMM...
Page 324: ...316 Netfinity Server HMM...
Page 325: ...Related service information 317...
Page 326: ...318 Netfinity Server HMM...
Page 327: ...Related service information 319...
Page 340: ...332 Netfinity Server HMM...
Page 341: ...Related service information 333...
Page 346: ...338 Netfinity Server HMM...
Page 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...