Error Code/Symptom
FRU/Action
089-XXX-001
(Failed Microprocessor test)
1. VRM for
Microprocessor
2. Microprocessor
089-XXX-002
(Failed Optional
Microprocessor test)
1. VRM for Optional
Microprocessor
2. Optional
Microprocessor
165-XXX-000
(Failed System Board test)
1. System Board Before
replacing the system
board, ensure that
system board jumper
J51 is not installed (the
default) when the error
occurs.
2. Processor Board
3. Power Backplane
4. Hot-Swap Drive
Backplane
175-XXX-001
(Failed Fan 1 test)
1. Fan 1
175-XXX-002
(Failed Fan 2 test)
1. Fan 2
175-XXX-003
(Failed Fan 2 test)
1. Fan 3
175-XXX-004
(Processor Board
Temperature sensor out of
range)
1. Check system
cooling
180-XXX-000
(Diagnostics LED failure)
1. Run Diagnostic LED
test for the failing
LED
180-XXX-001
(Failed Information Panel
LED test)
1. Information LED
Panel
2. Power-on Panel
180-XXX-002
(Failed Diagnostics LED
Panel test)
1. Diagnostics LED
Panel
2. Power-on Panel
180-XXX-003
(Failed System Board LED
test)
1. Run hot-swap PCI
latch test in Other
Devices under
Extended Tests
2. System Board
180-XXX-004
(Failed Processor Board
LED test)
1. Processor Board
2. System Board
180-XXX-005
(Failed SCSI Backplane
LED test)
1. SCSI Backplane
2. SCSI Backplane Cable
3. System Board
201-XXX-001
(Failed Memory test,
see“Memory settings” on
page 98 )
1. DIMM Location J1
Netfinity 5500 - Type 8660
273
Summary of Contents for 866011U - Netfinity 5500 - 8660
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Page 244: ...Screws 236 Netfinity Server HMM...
Page 247: ...Netfinity 5500 Type 8660 239...
Page 314: ...306 Netfinity Server HMM...
Page 324: ...316 Netfinity Server HMM...
Page 325: ...Related service information 317...
Page 326: ...318 Netfinity Server HMM...
Page 327: ...Related service information 319...
Page 340: ...332 Netfinity Server HMM...
Page 341: ...Related service information 333...
Page 346: ...338 Netfinity Server HMM...
Page 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...