All data from the array is lost, regardless of the
RAID levels assigned to the logical drives.
To replace a faulty drive:
1. Before you remove or replace a drive that you
suspect to be defective, verify that the drive is
defective. To do this:
a. Check the drive for damage.
b. Verify that the drive is positioned correctly. If the
drive is not installed correctly, reposition the
drive.
c. Check the lights on the drive tray. (See the
following information for a description of the
lights.) Verify that you can remove the drive
safely.
The lights on the hot-swap drive tray provide
drive status information, as follows:
Hard Disk Activity Light: When this green
light is flashing, it indicates that the server
is accessing the drive.
Hard Disk Status Light: When this amber
light is lit continuously, it indicates that the
drive has failed. When the light flashes
slowly (one flash per second), it indicates
that the hard disk drive is part of a disk
array and is being rebuilt. When the light
flashes rapidly (three flashes per second), it
indicates that the controller is identifying the
drive. The drive
should not be replaced if
this light is blinking; the drive has just been
replaced and the disk array is being rebuilt.
2. Physically replace the defective drive or use an
existing RDY drive that has a capacity equal to or
greater than the drive that you are replacing as a
hot-spare replacement drive.
Attention
Removing the wrong hard disk drive might cause
loss of all data in the array.
.
a. To physically replace the defective hard disk
drive, follow the instructions in “Internal drive
installation” on page 197 and “Installing a drive
in a hot-swap bay” on page 203; then, follow the
instructions in “Understanding the drive rebuild
process” on page 131.
b. To rebuild the defunct drive to an existing RDY
drive, follow the instructions in “Understanding
the drive rebuild process” on page 131.
130
Netfinity Server HMM
Summary of Contents for 866011U - Netfinity 5500 - 8660
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Page 244: ...Screws 236 Netfinity Server HMM...
Page 247: ...Netfinity 5500 Type 8660 239...
Page 314: ...306 Netfinity Server HMM...
Page 324: ...316 Netfinity Server HMM...
Page 325: ...Related service information 317...
Page 326: ...318 Netfinity Server HMM...
Page 327: ...Related service information 319...
Page 340: ...332 Netfinity Server HMM...
Page 341: ...Related service information 333...
Page 346: ...338 Netfinity Server HMM...
Page 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...