Note
You can use the Administration and
Monitoring utility program to identify a
defunct drive and designate a replacement
drive without restarting the server. Review
the information in “Understanding the drive
rebuild process” on page 131; then, see
“Using the Administration and Monitoring
Utility Program” on page 26 for more
information.
Understanding the drive rebuild process:
This
section contains guidelines and instructions for rebuilding a
defunct (DDD) drive using the ServeRAID Configuration
program.
If you are using the Administration and Monitoring utility
program, review the guidelines and information in this
section; then, see “Physical device administration” on
page 42 for instructions.
Automatic rebuild process:
The ServeRAID
controller will rebuild a defunct drive automatically when all
of the following conditions exist:
The physical drive that failed is part of a RAID level 1
or 5 logical drive.
A HSP or SHS drive with a capacity equal to or
greater than the original drive is available the moment
that the drive fails.
No rebuild, synchronization, or RAID level change
operation is in progress.
If multiple hot-spare drives are available, the ServeRAID
controller searches all bays for a hot-spare drive of the
appropriate size. The first drive that meets this
requirement enters the rebuild state.
A physical hard disk drive can enter the rebuild (RBL) state
if:
You physically replace a defunct drive that is part of
the critical (CRT) logical drive.
When you physically replace a defunct drive in a
critical (CRT) logical drive, the ServeRAID controller
rebuilds the data on the new physical drive
before it
changes the logical drive state back to Okay (OKY).
The ServeRAID controller adds a hot-spare or a
standby hot-spare drive to the array and changes its
state from HSP or SHS to RBL.
A ready or standby drive replaces a defunct drive that
is part of the critical (CRT) logical drive.
Guidelines for Rebuilding a Drive
Before you rebuild a drive, review the following guidelines:
Netfinity 5500 - Type 8660
131
Summary of Contents for 866011U - Netfinity 5500 - 8660
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Page 244: ...Screws 236 Netfinity Server HMM...
Page 247: ...Netfinity 5500 Type 8660 239...
Page 314: ...306 Netfinity Server HMM...
Page 324: ...316 Netfinity Server HMM...
Page 325: ...Related service information 317...
Page 326: ...318 Netfinity Server HMM...
Page 327: ...Related service information 319...
Page 340: ...332 Netfinity Server HMM...
Page 341: ...Related service information 333...
Page 346: ...338 Netfinity Server HMM...
Page 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...